Impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes
نویسندگان
چکیده
BACKGROUND Proton beam therapy is promising for the treatment of head and neck cancer (HNC), but it is sensitive to uncertainties in patient positioning and particle range. Studies have shown that the planning target volume (PTV) concept may not be sufficient to ensure robustness of the target coverage. A few planning studies have considered irradiation of unilateral HNC targets with protons, but they have only taken into account the dose on the nominal plan, without considering anatomy changes occurring during the treatment course. METHODS Four pencil beam scanning (PBS) proton therapy plans were calculated for 8 HNC patients with unilateral target volumes: single-field (SFO) and multi-field optimized (MFO) plans, either using the PTV concept or clinical target volume (CTV)-based robust optimization. The dose was recalculated on computed tomography (CT) scans acquired during the treatment course. Doses to target volumes and organs at risk (OARs) were compared for the nominal plans, cumulative doses considering anatomical changes, and additional setup and range errors in each fraction. If required, the treatment plan was adapted, and the dose was compared with the non-adapted plan. RESULTS All nominal plans fulfilled the clinical specifications for target coverage, but significantly higher doses on the ipsilateral parotid gland were found for both SFO approaches. MFO PTV-based plans had the lowest robustness against range and setup errors. During the treatment course, the influence of the anatomical variation on the dose has shown to be patient specific, mostly independent of the chosen planning approach. Nine plans in four patients required adaptation, which led to a significant improvement of the target coverage and a slight reduction in the OAR dose in comparison to the cumulative dose without adaptation. CONCLUSIONS The use of robust MFO optimization is recommended for ensuring plan robustness and reduced doses in the ipsilateral parotid gland. Anatomical changes occurring during the treatment course might degrade the target coverage and increase the dose in the OARs, independent of the chosen planning approach. For some patients, a plan adaptation may be required.
منابع مشابه
Multi-scenario based robust intensity-modulated proton therapy (IMPT) plans can account for set-up errors more effectively in terms of normal tissue sparing than planning target volume (PTV) based intensity-modulated photon plans in the head and neck region
BACKGROUND In a previous report, we compared the conformity of robust intensity-modulated proton therapy (IMPT) plans with that of helical tomotherapy plans for re-irradiations of head and neck carcinomas using a fixed set-up error of 2 mm. Here, we varied the maximum set-up errors between 0 and 5 mm and compared the robust IMPT-plans with planning target volume (PTV) based intensity-modulated ...
متن کاملA single-field integrated boost treatment planning technique for spot scanning proton therapy
PURPOSE Intensity modulated proton therapy (IMPT) plans are normally generated utilizing multiple field optimization (MFO) techniques. Similar to photon based IMRT, MFO allows for the utilization of a simultaneous integrated boost in which multiple target volumes are treated to discrete doses simultaneously, potentially improving plan quality and streamlining quality assurance and treatment del...
متن کاملFeasibility of automated proton therapy plan adaptation for head and neck tumors using cone beam CT images.
BACKGROUND Intensity modulated proton therapy (IMPT) of head and neck (H&N) tumors may benefit from plan adaptation to correct for the dose perturbations caused by weight loss and tumor volume changes observed in these patients. As cone beam CT (CBCT) is increasingly considered in proton therapy, it may be possible to use available CBCT images following intensity correction for plan adaptation....
متن کاملPretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)
Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...
متن کاملComparison of Absorbed Dose in Thyroid and Lens as Organs at Risk Between in vivo Dosimetry and 3-D Treatment Planning Calculation in Head and Neck Radiotherapy by Linac Beam
Introduction: Critical organs and structures may receive significant amounts of irradiation even if they are not the target of radiotherapy or located outside the treatment field. Although the sensitive thyroid gland and lens are not directly the targets of treatment, they can be affected by irradiation during the treatment of tumours in head and neck region. The purpose of thi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2017