Calibration Procedure and Uncertainty Analysis of an Electronic Scale Based on Two-current Source Supplied Circuit
نویسندگان
چکیده
Original scientific paper The article presents the prototype version of an original weight scale in which a non-conventional supplying circuit of strain gauge load cells is applied. The paper discusses construction of an electrical circuit, the way of strain gauge transducer connection and the measuring procedure. As far as the authors know, this novel electrical circuit and its application in a weight scale system have never been mentioned in literature. The specifications for directreading weight scales typically include readability, repeatability, linearity and eccentricity. The values of these parameters were estimated and used for calculation of the weight measurement uncertainty in the tested measuring range of the designed device.
منابع مشابه
A New Configuration for Power Sharing of Two Z-Source Inverters
This paper presents a new structure to provide the ability for power sharing of two Z-source inverters. According to the operation principles of Z-source inverters, only one input source supplies the circuit, which is a limitation particularly for the stand alone systems feeded by limited output power such as photovoltaics and feul cells. Furthermore; if one source fails to supply, the lo...
متن کاملInvestigating Characteristics of N2, CO2 and CF3I in Contrast to High Current Arcs in Circuit Breakers to Choose a Suitable Substitute for SF6
Specific and sensitive operation of circuit breakers makes an individual position for them in power networks. Circuit breakers are at the central gravity of variations and execution operations. Therefore, an optimum operation is the main reason to investigate about new gases to be used in MV and HV circuit breakers instead of SF6. The arc process has enormous complexity because of hydrodynamic ...
متن کاملCascaded Multilevel Inverter Based on Quasi-Z-Source Converter: Analysis, Design and Study of Optimal Structures
In this paper, a new topology for cascaded multilevel inverter based on quasi-Z-source converter is proposed. In the proposed topology the magnitude of output DC voltage is not limited to the sum of magnitude of DC voltage sources. Moreover, the reliability of the circuit due to capability of short circuit by Z-source network is increased. The quasi-Z- source converter in different modes is ana...
متن کاملUncertainty Analysis in MRI-based Polymer Gel Dosimetry
Background: Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin I...
متن کاملA Micropower Current-Mode Euclidean Distance Calculator for Pattern Recognition
In this paper a new synthesis for circuit design of Euclidean distance calculation is presented. The circuit is implemented based on a simple two-quadrant squarer/divider block. The circuit that employs floating gate MOS (FG-MOS) transistors operating in weak inversion region, features low circuit complexity, low power (<20uW), low supply voltage (0.5V), two quadrant input current, wide dyn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -