Molar distalization with a miniscrew-anchored sliding jig.

نویسندگان

  • Joong-Ki Lim
  • Hyun Ju Jeon
  • Jae Hoon Kim
چکیده

VOLUME XLV NUMBER 7 The opinions expressed in the Journal of Clinical Orthodontics are those of the writers and do not necessarily reflect the opinions and policies of JCO. Copyright © 2011 JCO, Inc. Journal of Clinical Orthodontics (USPS 802-120, ISSN 0022-3875) is published monthly for $260 per year (U.S. individual rate) by JCO, Inc., 1828 Pearl St., Boulder, CO 80302-5519. Periodicals postage paid at Boulder, CO, and additional mailing office. POSTMASTER: Send address changes to JCO, 1828 Pearl St., Boulder, CO 80302-5519. Phone: (303) 443-1720; e-mail: [email protected]. The material in each issue of JCO is protected by copyright. Instructions and fees for copying articles from JCO are available from the Copyright Clearance Center, (978) 750-8400; www.copyright.com. VOLUME XLV NUMBER 7 JULY 2011

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distalization with the miniscrew-supported EZ Slider auxiliary.

I molar-distalization appliances that require little or no patient compliance—including the Pendulum, Distal Jet, and sliding jigs1-3— have been developed as alternatives to headgear. To avoid the anchorage loss that often occurs with these devices, skeletal anchorage has increasingly been employed,4-6 leading to the introduction of new systems. This article introduces the EZ Slider* sliding au...

متن کامل

Dentoalveolar class III treatment using retromolar miniscrew anchorage

In this article, we report the successful use of miniscrews in the distalization of the lower dentition to correct an Angle class III malocclusion with lower anterior crowding in a dolichofacial adult patient. Conventional intraoral and extraoral appliances have many disadvantages, including the need for patient cooperation, potential for anchorage loss, and vertical extrusion of upper molars a...

متن کامل

The Implant Distal Jet.

M olar distalization for the treatment of Class II malocclusions has historically depended on patient compliance with intra-and extraoral auxiliaries. 1-5 In recent years, " non-compliance " devices such as the Distal Jet,* 6,7 Jones Jig,* 8 Pendulum,** 9 and repelling magnets 10 have been developed. The problem of anchorage loss during molar distaliza-tion with these appliances has not been so...

متن کامل

The Indirect Palatal Miniscrew Anchorage and Distalization Appliance.

The iPanda is fabricated on the patient’s working cast. An .035" round stainless steel wire is bent with a Young plier to produce a 12mm-long, 2mm-wide loop, which is then customized to create a self-locking system between the iPanda and the midpalatal miniscrew heads. This system allows easy and quick connection to and removal from the miniscrews without the need for ligatures or composite mat...

متن کامل

Effects of Jones Jig Appliance in Maxillary First Molar Distalization

The purpose of this study was to evaluate treatment effects of Jones jig appliance during class-II molar correction with a focus on the magnitude of maxillary first molar distalization, its tipping, extrusion and rotation as well as anchorage loss at premolarincisor unit. A complete set of pre and post distalization records including history, clinical examination, Lateral cephalometric radiogra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical orthodontics : JCO

دوره 45 7  شماره 

صفحات  -

تاریخ انتشار 2011