Viability of impacted bone allografts under metal mesh at the calcar in revision surgery of the hip.

نویسندگان

  • M Buttaro
  • G S Araujo
  • E S Araujo
  • F Comba
  • F Piccaluga
چکیده

Metal meshes are used in revision surgery of the hip to contain impacted bone grafts in cases with cortical or calcar defects in order to provide rotational stability to the stem. However, the viability of bone allografts under these metal meshes has been uncertain. We describe the histological appearances of biopsies obtained from impacted bone allografts to the calcar contained by a metal mesh in two femoral reconstructions which needed further surgery at 24 and 33 months after the revision procedure. A line of osteoid and viable new bone was observed on the surface of necrotic trabeculae. Active bone marrow between these trabeculae showed necrotic areas in some medullary spaces with reparative fibrous tissue and isolated reactive lymphocytes. This is interpreted as reparative changes after revascularisation of the cancellous allografts. These pathological findings are similar to those reported in allografts contained by cortical host bone and support the hypothesis that incorporation of morcellised bone under metal meshes is not affected by these devices.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proximal femoral allografts in revision hip arthroplasty.

We followed prospectively 69 patients with 78 proximal femoral allografts performed for revision of total hip arthroplasty for an average of 36 months (range 29 to 68). Large fragment proximal femoral allografts and cortical strut allografts were successful in 85%. Grafts smaller than 3 cm in length (calcar grafts) were clinically successful in 81%, but 50% underwent significant radiographic re...

متن کامل

Complete Bone Remodeling after Calcar Reconstruction with Metal Wire Mesh and Impaction Bone Grafting: a Case Report

We report the histological findings of a reconstructed calcar region four years after femoral impaction bone grafting using metal wire mesh for a case with massive defect of the proximal part of the femur. Thin cortical bone was formed just beneath the metal wire mesh and viable trabecular bone containing a small amount of granulation tissue was observed even at the bone-cement interface. Almos...

متن کامل

Filling of segmental bone defects in revision knee arthroplasty using morsellized bone grafts contained within a metal mesh.

For revision knee surgery with uncontained tibial bone defects, the authors report the containment of compacted morsellized allograft using metal-wire mesh, followed by implantation of a cemented total knee prosthesis. This method is comparable to the "impaction grafting technique" described for revision hip surgery and could be an alternative to metal wedges, augmented components, custom-made ...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

Vancomycin-supplemented impacted bone allografts in infected hip arthroplasty. Two-stage revision results.

Bone allografts can store and release high levels of vancomycin. We present our results of a two-stage treatment for infected hip arthroplasty with acetabular and femoral impaction grafting using vancomycin-loaded allografts. We treated 29 patients (30 hips) by removal of the implants, meticulous debridement, parenteral antibiotic therapy and second-stage reconstruction using vancomycin-supplem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 90 2  شماره 

صفحات  -

تاریخ انتشار 2008