Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study

نویسندگان

  • Si-Hoon Jo
  • Kyoung-Il Kim
  • Jae-Min Seo
  • Kwang-Yeob Song
  • Ju-Mi Park
  • Seung-Geun Ahn
چکیده

PURPOSE The purpose of this study was to compare the accuracy of the implant master cast according to the type (pick-up, transfer) and the length (long, short) of the impression copings. MATERIALS AND METHODS The metal master cast was fabricated with three internal connection type implant analogs (Osstem GS III analog), embedded parallel and with 10° of mesial angulation to the center analog. Four types of impression coping were prepared with different combinations of types (transfer, pick-up) and lengths (long, short) of the coping. The impressions were made using vinyl polysiloxane (one step, heavy + light body) with an individual tray, and 10 impressions were made for each group. Eventually, 40 experimental casts were produced. Then, the difference in the distance between the master cast and the experimental cast were measured, and the error rate was determined. The analysis of variance was performed using the SPSS (v 12.0) program (α = .05), and the statistical significance was set at P < .05. RESULTS The ANOVA showed that the pick-up type impression coping exhibited a significantly lower error rate than the transfer type. However, no significant difference was observed with respect to the length of the impression coping. Additionally, no significant difference was observed between the parallel and mesial angulated groups. CONCLUSION Within the limitations of this study, the pick-up type impression coping exhibited a more accurate implant master cast than the transfer type in parallel group. The accuracy of the implant master cast did not differ for different lengths of impression coping of at least 11 mm. Additionally, the accuracy of the implant cast was not different for the parallel and 10° mesial angulated groups.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study.

BACKGROUND With regard to implant-supported prostheses, to date no technique has been proven to guarantee a completely passive fit of prosthetic frameworks. Several clinical variables may affect the precision of impressions, particularly in the presence of implants. PURPOSE To compare the accuracy of implant impressions made with different materials, lengths of impression coping connections, ...

متن کامل

The accuracy of implant impressions: a systematic review.

STATEMENT OF PROBLEM Various implant impression techniques, such as the splint, pick-up, and transfer techniques, have been introduced, and some techniques may be more accurate than others. Also, clinically, some factors, including the angulation or depth of implants, may affect the accuracy of the implant impressions. PURPOSE The purposes of this review were to: (1) investigate the accuracy ...

متن کامل

تعیین دقت ثبت ایمپلنت و جزئیات سطحی با استفاده از پلی‌اتر و پلی‌وینیل سایلوکسان با روش تری بسته

  Background and Aims: Making accurate impressions of prepared teeth when they are adjacent to dental implants is of great importance. In these situations, disregarding the selection of appropriate impression material and technique, not only can affect accuracy of transferring of the 3-dimentional spatial status of implant, but also can jeopardize the accurate recording of tooth. In the present...

متن کامل

Effect of Impla Fix and Duralay Acrylic Resin Splinting Materials on Dimensional Changes of Direct Implant Impressions

Background and Aim: Making impression of several implants simultaneously for fabrication of dental prosthesis is challenging for many clinicians. Splinting can be performed for highly accurate impression making and better adaptation of prostheses. This study aimed to assess the effect of Impla and Duralay acrylic resin splinting materials on dimensional changes of direct implant impressions. ...

متن کامل

Accuracy of two impression techniques with angulated implants.

STATEMENT OF PROBLEM Accurate recording of implant locations is required so that definitive restorations are properly supported and do not place additional stress on the implants. Angulated implants may result in inaccurate impressions, and the impression technique may affect the accuracy of the definitive cast. PURPOSE The purpose of this study was to determine the effect the combined intera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2010