Sensitivity Distribution Simulations of Impedance Tomography Electrode Combinations

نویسندگان

  • P. Kauppinen
  • J. Hyttinen
  • J. Malmivuo
  • Ragnar Granit
چکیده

As reconstruction techniques generating images in electrical impedance tomography (EIT) are sensitive to noise, small errors on measured data can result into large errors in final images. In order to optimize the signal acquisition from any region, measurement should possess highest sensitivity and selectivity in that region. This study was conducted to estimate measurement properties of various generally applied measurement schemes in EIT. Computer models were utilized in simulating the sensitivity distributions of neighboring, cross, opposite and adaptive methods. Highest sensitivities were obtained with the cross and opposite methods, whereas neighboring was the least sensitive, when investigating a single measurement. Maximum proportional selectivities in the centre of a 2D model were 100, 94, 88 and 62 %, respectively, as compared between the neighboring, cross, opposite and adaptive methods. In 3D, the corresponding values were 100, 55, 50 and 7.6 %. Adaptive method is flexible in current injection, yet trigonometric injection was used for simplicity, explaining the poor performance. Regions of negative sensitivity were detected, which may complicate the reconstruction. Nevertheless, studying sensitivity distributions may improve the outcome of EIT. In future, anatomically realistic models are utilized to derive measurements optimizing the sensitivity in the inner structures of the model. Keywords—EIT, electrode configuration, lead field, modeling, sensitivity distribution

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An impedance method for spatial sensing of 3D cell constructs--towards applications in tissue engineering.

We present the characterisation and validation of multiplexed 4-terminal (4T) impedance measurements as a method for sensing the spatial location of cell aggregates within large three-dimensional (3D) gelatin scaffolds. The measurements were performed using an array of four rectangular chambers, each having eight platinum needle electrodes for parallel analysis. The electrode positions for curr...

متن کامل

The impact of electrode area, contact impedance and boundary shape on EIT images.

Electrical impedance tomography (EIT) measures the conductivity distribution within an object based on the current applied and voltage measured at surface electrodes. Thus, EIT images are sensitive to electrode properties (i.e. contact impedance, electrode area and boundary shape under the electrode). While some of these electrode properties have been investigated individually, this paper inves...

متن کامل

A Local Region of Interest Imaging Method for Electrical Impedance Tomography with Internal Electrodes

Electrical Impedance Tomography (EIT) is a very attractive functional imaging method despite the low sensitivity and resolution. The use of internal electrodes with the conventional reconstruction algorithms was not enough to enhance image resolution and accuracy in the region of interest (ROI). We propose a local ROI imaging method with internal electrodes developed from careful analysis of th...

متن کامل

Assessment of electrical impedance endotomography for hardware specification

PURPOSE The purpose of the study is the quantitative assessment of Electrical Impedance Endotomography (EIE) for the specification of hardware systems. EIE is a modality of Electrical Impedance Tomography (EIT) where the electrodes are located on a probe placed in the middle of the region of interest. The absence of material boundary to the explored volume and the decrease in sensitivity away f...

متن کامل

Electrical impedance tomography with compensation for electrode positioning variations.

Ideally electrical impedance tomography (EIT) should not be oversensitive to electrode positions, but this conflicts with efforts to produce high-resolution images. Two procedures are presented that balance reducing the sensitivity to electrode position errors with generating practicable EIT images. The first provides a criterion based on electrode sensitivity for regularizing the reconstructio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005