Capillary zone electrophoresis / electrospray mass spectrometry of priority phenols
نویسندگان
چکیده
Eleven priority phenols were separated by capillary zone electrophoresis (CZE) and detected on-line with electrospray ionization mass spectrometry (ESI-MS) in the negative-ion mode. Parameters critical to the coupling of CZE and MS were studied. The best result was obtained with 2-[N-cyclohexylaminolethanesulfonic acid (CHES) as the running buffer and a solution of water-2-propanol (20:80) containing 0.5% ammonia as the sheath liquid. With the use of field amplification as the preconcentration technique and the mass spectrometer operated in the selected ion monitoring mode, the detection limit of most phenols was found to be in the range of 50 ppb. This method has been successfully applied to the determination of pentachlorophenol in a paper clay sample.
منابع مشابه
Rapid Biomolecule Analysis Using Two-dimensional Electrophoresis-electrospray Ionization Microchip
We demonstrate a two-dimensional (2D) separation microchip allowing capillary isoelectric focusing-capillary zone electrophoresis (cIEF-CZE) to be coupled to electrospray ionization mass spectrometry (ESI/MS). In the first dimension, separation is according to pI values (cIEF), while CZE occurs in the second dimension during mobilization towards the monolithically integrated ESI emitter. The se...
متن کاملAnalysis of drugs of forensic interest with capillary zone electrophoresis/time-of-flight mass spectrometry based on the use of non-volatile buffers.
The present work is aimed at investigating the influence of the background electrolyte composition and concentration on the separation efficiency and resolution and mass spectrometric detection of illicit drugs in a capillary zone electrophoresis-electrospray ionization-time of flight mass spectrometry (CZE-ESI-TOF MS) system. The effect of phosphate, borate and Tris buffers on the separation a...
متن کاملLiquid chromatography-mass spectrometry and strategies for trace-level analysis of polar organic pollutants.
Liquid chromatography-mass spectrometry using atmospheric pressure ionization (LC-API-MS) has drastically changed the analytical methods used to detect polar pollutants in water. The present status of application of this technique to organic water constituents is reviewed. The selection of the appropriate LC conditions, whether reversed-phase liquid chromatography, ion-pair chromatography, capi...
متن کاملBottom-Up Proteomics of Escherichia coli Using Dynamic pH Junction Preconcentration and Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry
We report the use of the dynamic pH junction based capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry (CZE-ESI-MS/MS) for bottom-up proteomics with an electrokinetically pumped sheath-flow nanospray capillary electrophoresis-mass spectrometry (CE-MS) interface and both LTQ-XL and LTQ-Orbitrap-Velos mass spectrometers. Conventional injection of 20 nL of a 1 mg/mL BSA...
متن کاملDetection and identification of rabbit liver metallothionein-2 subisoforms by capillary zone electrophoresis - inductively coupled plasma mass spectrometry and microbore HPLC - electrospray mass spectrometry
To date, most of works concerning metallothioneins have been referring either to the MT-fraction (as isolated by gel filtration) or to two MT-isoforms resulting from the further fractionation of the MT-fraction by anion-exchange chromatography into MT-1 (eluting first) and MT-2 (eluting second). However, a further characterization of these fractions by reversed-phase HPLC [1] and capillary zone...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2003