Reevaluation of the power of error detection of Westgard multirules.
نویسنده
چکیده
References 1. Zerbini M, Musiani M. Human parvoviruses. In: Murray PR, Baron EJ, Jorgensen JH, Pfaller MA, Yolken RH, eds. Manual of clinical microbiology, 8th ed. Washington: ASM Press, 2003:1534–43. 2. Gallinella G, Zuffi E, Gentilomi G, Manaresi E, Venturoli S, Bonvicini F, et al. Relevance of B19 markers in serum samples for a diagnosis of parvovirus B19-correlated diseases. J Med Virol 2003;71:135–9. 3. Tabor E, Epstein JS. NAT screening of blood and plasma donations: evolution of technology and regulatory policy. Transfusion 2002;42: 1230–7. 4. Rasmussen R. Quantification on the LightCycler. In: Meuer S, Wittwer C, Nakagawara K, eds. Rapid cycle real-time PCR: methods and application. Berlin: Springer, 2001:21–34. 5. Mackay IM, Arden KE, Nitsche A. Real-time PCR in virology. Nucleic Acids Res 2002;30:1292–305. 6. Pfaffl MW. A new mathematical model for relative quantification in real-time RT-PCR. Nucleic Acids Res 2001;29:2002–7. 7. Manaresi E, Gallinella G, Zuffi E, Bonvicini F, Zerbini M, Musiani M. Diagnosis and quantitative evaluation of parvovirus B19 infections by real-time PCR in the clinical laboratory. J Med Virol 2002;67:275–81. 8. Harder TC, Hufnagel M, Zahn K, Beutel K, Schmitt H-J, Ullmann U, et al. New LightCycler PCR for rapid and sensitive quantification of parvovirus B19 DNA guides therapeutic decision-making in relapsing infections. J Clin Microbiol 2001;39:4413–9. 9. Aberham C, Pendl C, Gross P, Zerlauth G, Gessner M. A quantitative, internally controlled real-time PCR Assay for the detection of parvovirus B19 DNA. J Virol Methods 2001;92:183–91. 10. Gruber F, Falkner FG, Dorner F, Hammerle T. Quantitation of viral DNA by real-time PCR applying duplex amplification, internal standardization, and two-color fluorescence detection. Appl Environ Microbiol 2001;67:2837–9. 11. International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH). Guidelines for validation of analytical procedures (Q2A) and methodology (Q2B). http:// www.ich.org. (Q2A, October 1995; Q2B, November 1996). 12. Saldanha J, Lelie N, Yu MW, Heath A. Establishment of the first World Health Organization International Standard for human parvovirus B19 DNA nucleic acid amplification techniques. Vox Sang 2002;82:24–31. 13. Gallinella G, Moretti E, Nardi G, Zuffi E, Bonvicini F, Bucci E, et al. Analysis of B19 virus contamination in plasma pools for manufacturing, by using a competitive polymerase chain reaction assay. Vox Sang 2002;83:324–31. 14. Siegl S, Cassinotti P. Presence and significance of parvovirus B19 in blood and blood products. Biologicals 1998;26:89–94.
منابع مشابه
Improved Detection of Serum Estradiol after Sample
application of the cross-run rules. Data were also modeled for n 4, and the error detection for full multirules was lower than described on the Westgard site for all changes in bias from 1.0 to 3.0 times the SD when previously detected shifts were removed from the 8x rule (data not shown). The change in bias that can be detected with 90% certainty decreases from 1.8 times the SD, as shown on th...
متن کاملShould I repeat my 1:2s QC rejection?
BACKGROUND Repeating a QC that is outside 2SD from the mean (1:2s rule) appears to be a common practice. Although this form of repeat sampling is frowned on by many, the comparative power of the approach has not been formally evaluated. METHODS We computed power functions mathematically and by computer simulation for 4 different 1:2s repeat-sampling strategies, as well as the 1:2s rule, the 1...
متن کاملAnalysis and Diagnosis of Partial Discharge of Power Capacitors Using Extension Neural Network Algorithm and Synchronous Detection Based Chaos Theory
Power capacitors are important equipment of the power systems that are being operated in high voltage levels at high temperatures for long periods. As time goes on, their insulation fracture rate increases, and partial discharge is the most important cause of their fracture. Therefore, fast and accurate methods have great importance to accurately diagnosis the partial discharge. Conventional me...
متن کاملError Analysis, Design and Modeling of an Improved Heterodyne Nano-Displacement Interferometer
A new heterodyne nano-displacement with error reduction is presented. The main errors affecting the displacement accuracy of the nano-displacement measurement system including intermodulation distortion error, cross-talk error, cross-polarization error and phase detection error are calculated. In the designed system, a He-Ne laser having three-longitudinal-mode is considered as the stabiliz...
متن کاملReversible Logic Multipliers: Novel Low-cost Parity-Preserving Designs
Reversible logic is one of the new paradigms for power optimization that can be used instead of the current circuits. Moreover, the fault-tolerance capability in the form of error detection or error correction is a vital aspect for current processing systems. In this paper, as the multiplication is an important operation in computing systems, some novel reversible multiplier designs are propose...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 50 4 شماره
صفحات -
تاریخ انتشار 2004