Alternans of blood pressure and heart rate in dilated cardiomyopathy.

نویسندگان

  • Uwe Leder
  • Hans-Peter Pohl
  • Vico Baier
  • Matthias Baumert
  • Mario Liehr
  • Jens Haueisen
  • Andreas Voss
  • Hans R Figulla
چکیده

Impaired myocardial performance is known to be associated with electrical and mechanical beat-to-beat alternans phenomena. The alternans in blood pressure and heart rate and their interdependency in idiopathic dilated cardiomyopathy (IDC) were studied. The arterial blood pressure and the electrocardiograph (ECG) were continuously recorded in 22 patients suffering from IDC (age 49 +/- 13 years, ejection fraction 0.33 +/- 0.13, left ventricular diameter of 67 +/- 8 mm) and in 21 healthy controls (age 52 +/- 15 years). The beat-to-beat variations of the interbeat intervals (IBI) and of the blood pressure amplitudes (AMP) were measured. An alternans beat was defined as a beat preceded and followed by beats that had higher or lower values in the respective modality. The percentages of singular and repetitive alternans patterns, and the interdependency of the alternans patterns in AMP and IBI were assessed. The study found significantly more singular and repetitive alternans patterns in the IDC group compared to the control group both in the analysis of AMP and IBI (singular alternans in IBI: 55 +/- 11 vs 47 +/- 7%, P < 0.01; singular alternans in AMP: 61 +/- 15 vs 45 +/- 6%, P < 0.01; triple alternans in IBI: 29 +/- 18 vs 16 +/- 9%, P < 0.01; triple alternans in AMP: 34 +/- 24 vs 12 +/- 7%, P < 0.01). The amplitudes of the AMP alternans patterns were higher in IDC compared to controls (9 +/- 7 vs 4 +/- 2% of AMP, P = 0.01) whereas they did not differ in IBI. The correlation analysis revealed a significant interdependency of the alternans pattern in IBI and AMP in 18 of 22 IDC patients and in 12 of 21 controls (r = 0.50 +/- 0.21 [IDC]; r = 0.26 +/- 0.05 [controls]). The slope of the linear regression (delta AMP vs delta IBI) was steeper in the IDC group compared to the control group (62 +/- 50 vs 20 +/- 22 mmHg/s, P < 0.01). The percentages of alternans patterns appearing in IBI and AMP were positively correlated to the left ventricular diameter (r = 0.70 in the IBI, and r = 0.30 in the AMP). The blood pressure amplitude and the heart rate did not differ between the two groups. Patients suffering from IDC have a higher prevalence, stability, amplitude, and interdependency of alternans patterns in IBI and AMP compared to the control group. The amount of alternans patterns indicates the stage of disease. The alternans analysis may have impact on the functional assessment of patients suffering from heart failure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prognostic value of pacing-induced mechanical alternans in patients with mild-to-moderate idiopathic dilated cardiomyopathy in sinus rhythm.

OBJECTIVES The relation between the occurrence of pacing-induced mechanical alternans and prognosis in patients with mild-to-moderate idiopathic dilated cardiomyopathy (IDCM) in sinus rhythm was investigated prospectively. The myocardial expression of genes for Ca2+-handling proteins in such patients was also examined. BACKGROUND Mechanical alternans occurs in some patients with severe heart ...

متن کامل

Decline of plasma brain natriuretic peptide level after carvedilol therapy to treat dilated cardiomyopathy presenting with mechanical alternans.

Mechanical alternans is observed in patients with severe left ventricular dysfunction. We report a case of dilated cardiomyopathy with mechanical alternans. He presented with a remarkable decrease in plasma brain natriuretic peptide (BNP) levels after beta-blocker therapy despite persistency of the mechanical alternans. Mechanical alternans may persist after improvement of hemodynamics, diastol...

متن کامل

Pulsus alternans determined by biventricular simultaneous systolic time intervals.

This investigation was performed to determine the presence of unilateral or bilateral pulsus alternans in the systemic and pulmonary circulations in heart failure and to estimate the prevalence of pulsus alternans in congestive cardiomyopathy. The subjects were 36 adult patients in heart failure due to a variety of cardiopulmonary diseases. We measured left- and right-sided systolic time interv...

متن کامل

Multiple autonomic and repolarization investigation of sudden cardiac death in dilated cardiomyopathy and controls.

BACKGROUND Prophylactic defibrillator implantation is recommended in dilated, nonischemic heart disease and left ventricular ejection fraction of ≤0.30 to 0.35. Noninvasive testing should improve accuracy in decision making of prophylactic defibrillator implantation. METHODS AND RESULTS We enrolled 60 patients (median age, 57 years) with dilated cardiomyopathy and left ventricular ejection fr...

متن کامل

Dobutamine-Induced Mechanical Alternans

We investigated the relationship between the occurrence of dobutamine-induced mechanical alternans (MA) and prognosis in ambulatory patients with idiopathic dilated cardiomyopathy (IDCM). Recent American College of Cardiology and American Heart Association guidelines for the management of heart failure have emphasized the need for earlier identification and therapy for patients at high risk of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 25 9  شماره 

صفحات  -

تاریخ انتشار 2002