Energy expenditure of walking with prostheses: comparison of three amputation levels.
نویسندگان
چکیده
Amputee patients spend more energy during walking than able-bodied persons. It is generally accepted that more proximal amputation is associated with more energy need. However, the picture is not clear, especially for partial foot amputees. The purpose of this study was to compare the energy consumption of walking in traumatic unilateral amputees with three different amputation levels (trans-femoral, trans-tibial and partial foot amputations). Sixty-four male unilateral traumatic amputees participated in this study. Energy expenditure during walking was measured for four different speed and slope combinations: 1.5 km/h and 0 degrees slope, 3 km/h and 0 degrees slope, 1.5 km/h and 5 degrees slope, 3 km/h and 5 degrees slope. Mean O(2) consumption (ml/kg/min) of the last 2 min of each 5-min session was calculated. In all four combinations, energy expenditure of trans-tibial amputees was the lowest, and energy expenditure of trans-femoral amputees was the highest. Statistical significance, however, could not be obtained for the differences among the groups. In conclusion, walking of partial foot amputees does not seem to be more energy efficient than that of higher level amputees.
منابع مشابه
Energy expenditure and walking speed in lower limb amputees: a cross sectional study.
BACKGROUND Energy expenditure and walking speed are generally recommended for use as measures of status and outcome for walking. The objective of this study was to measure the physiological cost index (PCI) and comfort walking speed (CWS) at three levels of lower limb amputation: transfemoral, transtibial and Syme level, and the relationship of these physiological variables to prosthetic ambula...
متن کاملRating of Perceived Exertion as an Indicator of Exercise Intensity in Paraplegics
Background: Energy expenditure is of paramount importance in the assessment of usefulness of wheelchair for paraplegics. Despite widespread recognition of problems associated with currently available mobility systems for persons with spinal cord injuries, development of more efficient systems has been slow. Lack of a suitable and simple technique for the assessment of energy expenditure in par...
متن کاملComparing the Effect of New Silicone Foot Prosthesis and Conventional Foot Prosthesis on Plantar Pressure in Diabetic Patients With Transmetatarsal Amputation
Objective Diabetic foot ulcers are significant complications of diabetes that can lead to amputation. Partial foot prostheses can be used to redistribute the plantar pressure on the residual limb to alleviate local pressures and prevent re-amputation at more proximal levels. The current study aimed to describe the fabrication of an original silicone foot prosthesis designed for a diabetic patie...
متن کاملEnergy expenditure and gait characteristics of a bilateral amputee walking with C-leg prostheses compared with stubby and conventional articulating prostheses.
OBJECTIVE To compare energy cost and stride characteristics during walking with 3 different types of prostheses in a person with bilateral knee disarticulations. DESIGN Single-case study. Setting Pathokinesiology laboratory. PARTICIPANT A subject with bilateral knee disarticulations and bilateral transradial amputations secondary to meningococcemia with purpura fulminans. INTERVENTIONS No...
متن کاملمقایسه میزان رضایت بیماران از اندازههای ابعادی سوکت در 3 روش قالبگیری پروتز
Below knee amputation, which is noticed as one of the most common lower extremity amputations, is caused as a result of various factors like trauma, disease, or congenital limb deficiencies. In order to take these amputees back to daily life, below knee prostheses are used as an alternate to original limb. Comfort and patients’ satisfaction with prostheses are directly related to each prost...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Prosthetics and orthotics international
دوره 34 1 شماره
صفحات -
تاریخ انتشار 2010