In vivo dosimetry of thyroid doses from different irradiated sites in children and adolescents: a cross-sectional study

نویسندگان

  • Cassiane Cardoso Bonato
  • Henrique Bregolin Dias
  • Michele da Silva Alves
  • Lucas Ost Duarte
  • Telpo Martins Dias
  • Maiara Oliveira Dalenogare
  • Claudio Castelo Branco Viegas
  • Regina Helena Elnecave
چکیده

BACKGROUND Scattered radiation can be assessed by in vivo dosimetry. Thyroid tissue is sensitive to radiation, even at doses <10 cGy. This study compared the scattered dose to the thyroid measured by thermoluminescent dosimeters (TLDs) and the estimated one by treatment planning system (TPS). METHODS During radiotherapy to sites other than the thyroid of 16 children and adolescents, seventy-two TLD measurements at the thyroid were compared with TPS estimation. RESULTS The overall TPS/TLD bias was 1.02 (95% LA 0.05 to 21.09). When bias was stratified by treatment field, the TPS overestimated TLD values at doses <1 cGy and underestimated them at doses >10 cGy. The greatest bias was found in pelvis and abdomen: 15.01 (95% LA 9.16 to 24.61) and 5.12 (95% LA 3.04 to 8.63) respectively. There was good agreement in orbit, head, and spine: bias 1.52 (95% LA 0.48 to 4.79), 0.44 (95% LA 0.11 to 1.82) and 0.83 (0.39 to 1.76) respectively. There was small agreement with broad limits for lung and mediastinum: 1.13 (95% LA 0.03 to 40.90) and 0.39 (95% LA 0.02 to 7.14) respectively. CONCLUSIONS The scattered dose can be measured with TLDs, and TPS algorithms for outside structures should be improved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Autoimmune Thyroid Disorder in Children and Adolescents with Type I Diabetes Mellitus

Background Type one diabetes mellitus (Type 1 DM) is the most common type of diabetes in children and adolescents, arising through a complex interaction of immune, genetic and environmental factors. Autoimmune thyroid disease is the most frequent disorder associated with Type one diabetes mellitus. This study aimed to evaluate incidence of autoimmune thyroid disease in children and adolescents ...

متن کامل

Comparison of Absorbed Dose in Thyroid and Lens as Organs at Risk Between in vivo Dosimetry and 3-D Treatment Planning Calculation in Head and Neck Radiotherapy by Linac Beam

Introduction: Critical organs and structures may receive significant amounts of irradiation even if they are not the target of radiotherapy or located outside the treatment field. Although the sensitive thyroid gland and lens are not directly the targets of treatment, they can be affected by irradiation during the treatment of tumours in head and neck region. The purpose of thi...

متن کامل

Maxillofacial Fractures in CT scan Images of Adult, Adolescent, and Child Patients in Radiology Ward of Mashhad’s Shahid Kamyab Emergency Hospital in 2010

Introduction: This study was conducted to determine the pattern of maxillofacial fractures in three age groups of adults, adolescents, and children, using CT scan images. Methods: In this cross-sectional study, CT scan images of 230 patients with maxillofacial trauma during one year were examined in terms of the number and site of fractures. The patients were divided into three age groups, chil...

متن کامل

In Vivo Dosimetry Using a Flat Surface Sun Nuclear Corporation Diode in 60co Beams for Some Radiotherapy Treatments in Ghana

Introduction: One of the useful standard quality assurance techniques in radiation therapy is monitoring entrance doses in in-vivo dosimetry. An overall tolerance limit of 5% of the absorbed radiation dose has been recommended by the International Commission of Radiological Units. The implementation of an in vivo dosimet...

متن کامل

Experimental evaluation of midline dose calculation methods in In vivo dosimetry using anatomic thorax phantom

Background: In vivo dosimetry is a method for estimation of overall error in the delivered dose to the patients at the end of radiotherapy process. In this research, two methods for target dose calculation were evaluated on midline and central axis of photon beams in in vivo dosimetry of thorax fields. Materials and Methods: Entrance and exit doses for anterior and lateral fields of thorax were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014