Use of RODAC plates to measure containment of Mycobacterium tuberculosis in a Class IIB biosafety cabinet during routine operations.
نویسندگان
چکیده
OBJECTIVE/BACKGROUND Guidelines for the manipulation of Mycobacterium tuberculosis (MTB) cultures require a Biosafety Level 3 (BSL-3) infrastructure and accompanying code of conduct. In this study, we aimed to validate and apply detection methods for viable mycobacteria from surfaces in a BSL-3 MTB laboratory. METHODS We evaluated phenotypic (Replicate Organism Detection and Counting [RODAC] plates) and molecular (propidium monoazide [PMA]-based polymerase chain reaction [PCR]) approaches for the detection of viable mycobacteria, as well as the effect of 70% ethanol applied for 5min for disinfection against mycobacteria. For validation of the method, recovery of serial dilutions of Mycobacterium bovis bacillus Calmette-Guérin from glass slides was measured. Subsequently, we stamped surfaces in and around the biosafety cabinet (BSC) after different technicians had manipulated high bacterial load suspensions for routine drug-susceptibility testing in a Class II BSC. RESULTS RODAC stamping could detect as few as three bacteria on slides stamped either 5min or 60min after inoculation. PMA-based PCR, tested in parallel, did not pass validation. Mycobacteria were still detected after 5-min disinfection with ethanol 70%. In the BSL-3, from 201 RODAC-stamped surfaces, MTB was detected in four: three inside a BSC-on a tube cap and on an operator's gloves-and one outside, on an operator's gown. CONCLUSION RODAC plates detect mycobacteria at low numbers of microorganisms. In addition, this method allowed us to show that 70% ethanol does not reliably kill mycobacteria when applied for 5min to a dried surface, and that MTB bacilli may arrive outside a Class II BSC during routine practice, although the route could not be documented.
منابع مشابه
Einstein Contained Aerosol Pulmonizer (ECAP): Improved Biosafety for Multi-Drug Resistant (MDR) and Extensively Drug Resistant (XDR) Mycobacterium tuberculosis Aerosol Infection Studies.
A new apparatus enhances the biosafety of containment (biosafety level 3 [BSL-3]) and provides experimental reproducibility for aerosol infection experiments with MDR and XDR Mycobacterium tuberculosis. The methods are generally applicable to the study of airborne pathogens.
متن کامل1 Laboratory Biosafety in Containment Laboratories
Microbiological research on and diagnostics of highly pathogenic microorganisms, namely bacteria and viruses, have to be conducted in containment laboratories in order to contain the infectious material. We are therefore referring to the ‘‘Concept of Biocontainment’’ – a concept, which dates back to the 1940s, when the first biosafety cabinet (BSC) class III was developed at the US Army Biologi...
متن کاملEffects of airflow rates and operator activity on containment of bacterial aerosols in a class II safety cabinet.
Biological safety cabinets are frequently relied upon to provide sterile work environments in which hazardous microorganisms can be safely handled. Verification of correct airstream velocities does not, by itself, ensure that adequate protection will be achieved under all users. Instead, the concentration of microorganisms in a cabinet operator's breathing zone must be measured during typical c...
متن کاملFrancisella tularensis, Mycobacterium tuberculosis, Blastomyces dermatitidis, Venezuelan equine encephalitis virus, Chlamydia psittaci, and Coccidioides
Section I—Introduction Over the past two decades, Biosafety in Microbiological and Biomedical Laboratories (BMBL) has become the code of practice for biosafety—the discipline addressing the safe handling and containment of infectious microorganisms and hazardous biological materials. The principles of biosafety introduced in 1984 in the first edition of BMBL1 and carried through in this fifth e...
متن کاملThe Biological Weapons Convention: From International Obligations to Effective National Action
The objective of this study was to evaluate both condensing (wet) and non-condensing (dry) vaporous hydrogen peroxide (VHP) technologies for decontaminating a worst-case scenario Class II biosafety cabinet. A 23-year-old Class II, type A2 biosafety cabinet equipped with loaded HEPA filters and an inoperable blower was used for this study. Biological indicators were placed at various locations w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- International journal of mycobacteriology
دوره 5 2 شماره
صفحات -
تاریخ انتشار 2016