Correlation of blood volume values and pulmonary artery catheter measurements.

نویسندگان

  • Sadir J Alrawi
  • Leonidas S Miranda
  • Joseph N Cunningham
  • Anthony J Acinapura
  • Ramanathan Raju
چکیده

OBJECTIVE To correlate the values generated by direct total blood volume measurement with pulmonary artery catheter parameters and commonly used laboratory values in the management of critically ill patients. METHODS This study was carried out at the Lutheran Medical Center, Brooklyn, New York, United States of America, during the period 1998-1999. We prospectively correlated the total blood volume (TBV) values generated by the blood volume analyzer (BVA)-100 using I131-tagged albumin, with the values obtained from pulmonary artery catheter (PAC) of central venous pressure, pulmonary capillary wedge pressure, cardiac output, and with laboratory values of hematocrit, lactate, arterial blood gas and mixed venous blood, in critically ill patients. Twenty-four intensive care unit (ICU) patients were studied. INCLUSION CRITERIA Admission to the intensive care, pulmonary artery catheter insertion and (APACHE) II Acute Physiology and Chronic Health Evaluation score of 8-30 (mean=17.875). EXCLUSION CRITERIA Pediatric patients, hemodynamically normal or stable patients, pregnancy, and critically ill patients that were managed in an ICU setting without PAC catheter. Height and weight were recorded. After the collection of an initial blood sample (5 cc), one cc of I131-tagged albumin (15-25 microcuries) was injected using a patented syringe. Five venous samples were collected after the isotope injection. RESULTS The collection times were entered into the BVA-100. Hematocrit measurements were performed in duplicate. Blood samples were centrifuged and one ml from the plasma of each sample was pipetted (in duplicate) into the sample tube then placed into the BVA-100. The results showed that the TBV did not correlate with either pulmonary capillary wedge pressure or central venous pressure, and except for the cardiac output, there is no correlation between pulmonary capillary wedge pressure readings or TBV results and the other parameters considered in this study. CONCLUSION This method can be released from the research fields and can be safely incorporated into the clinical arena. It provides an accurate assessment of the volume status in intensive care unit patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Circulating blood volume measurements correlate poorly with pulmonary artery catheter measurements.

BACKGROUND Determination of the intravascular volume status of a critically ill surgical patient is paramount for appropriate fluid and cardiovascular management. Many clinical parameters have been utilized to estimate intravascular volume but none are precise indicators of circulating blood volume. The purpose of this observational pilot study was to compare measured blood volume with hemodyna...

متن کامل

Relationships between volume and pressure measurements and stroke volume in critically ill patients

OBJECTIVE To evaluate the relationships between the changes in stroke volume index (SVI), measured in both the aorta and the pulmonary artery, and the changes in intrathoracic blood volume index (ITBVI), as well as the relationship between changes in aortic SVI and changes in the pulmonary artery wedge pressure (PAWP). DESIGN Prospective study with measurements at predetermined intervals. S...

متن کامل

A prospective randomized trial using blood volume analysis in addition to pulmonary artery catheter, compared with pulmonary artery catheter alone, to guide shock resuscitation in critically ill surgical patients.

Measurement of blood volume (BV) may guide fluid and red blood cell management in critically ill patients when capillary leak from shock and fluid resuscitation makes assessment of intravascular volume difficult. This is a prospective randomized trial of critically ill surgical patients with septic shock, severe sepsis, severe respiratory failure, and/or cardiovascular collapse. The control gro...

متن کامل

Measurement of instantaneous blood flow velocity and pressure in conscious man with a catheter-tip velocity probe.

SUMMARY Twenty-three patients were investigated during diagnostic right and left cardiac catheterization with an electromagnetic catheter-tip velocity probe. The catheter contained a pressure lumen for simultaneous measurements of intravascular pressure. Average peak and mean blood velocities were 66 and 11 cm/sec in the ascending aorta, 57 and 10 cm/sec in the pulmonary artery, 28 and 12 cm/se...

متن کامل

Extravascular lung water measurements and hemodynamic monitoring in the critically ill: bedside alternatives to the pulmonary artery catheter.

The recently completed Fluid and Catheter Treatment Trial conducted by the National Institutes of Health ARDSNetwork casts doubt on the value of routine pulmonary artery catheterization for hemodynamic management of the critically ill. Several alternatives are available, and, in this review, we evaluate the theoretical, validation, and empirical databases for two of these: transpulmonary thermo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Saudi medical journal

دوره 23 11  شماره 

صفحات  -

تاریخ انتشار 2002