B1 mapping by Bloch-Siegert shift.
نویسندگان
چکیده
A novel method for amplitude of radiofrequency field (B1+) mapping based on the Bloch-Siegert shift is presented. Unlike conventionally applied double-angle or other signal magnitude-based methods, it encodes the B(1) information into signal phase, resulting in important advantages in terms of acquisition speed, accuracy, and robustness. The Bloch-Siegert frequency shift is caused by irradiating with an off-resonance radiofrequency pulse following conventional spin excitation. When applying the off-resonance radiofrequency in the kilohertz range, spin nutation can be neglected and the primarily observed effect is a spin precession frequency shift. This shift is proportional to the square of the magnitude of B1(2). Adding gradient image encoding following the off-resonance pulse allows one to acquire spatially resolved B(1) maps. The frequency shift from the Bloch-Siegert effect gives a phase shift in the image that is proportional to B(1)(2). The phase difference of two acquisitions, with the radiofrequency pulse applied at two frequencies symmetrically around the water resonance, is used to eliminate undesired off-resonance effects due to amplitude of static field inhomogeneity and chemical shift. In vivo Bloch-Siegert B(1) mapping with 25 sec/slice is demonstrated to be quantitatively comparable to a 21-min double-angle map. As such, this method enables robust, high-resolution B(1)(+) mapping in a clinically acceptable time frame.
منابع مشابه
Turbo Spin Echo Bloch Siegert Shift B1 Mapping
An interesting method for B1 mapping based on the Bloch-Siegert (BLS) shift was recently presented (1,2) for gradient echo (FLASH) and Spin Echo (SE) sequences. This method uses off-resonant pulses before signal acquisition to encode the B1 information into the signal phase. Fast B1 mapping is possible since the repetition time has only minor influence on the quality of the phase information. I...
متن کاملMotion-robust cardiac B1+ mapping at 3T using interleaved bloch-siegert shifts.
PURPOSE To develop and evaluate a robust motion-insensitive Bloch-Siegert shift based B1+ mapping method in the heart. METHODS Cardiac Bloch-Siegert B1+ mapping was performed with interleaved positive and negative off-resonance shifts and diastolic spoiled gradient echo imaging in 12 heartbeats. Numerical simulations were performed to study the impact of respiratory motion. The method was com...
متن کاملFast and Robust B1 Mapping at 7T by the Bloch-Siegert Method
Introduction: B1 mapping has a variety of applications including the design of RF pulses in parallel transmit systems, and flip angle calibration for T1 mapping. Many existing B1 mapping methods suffer from T1 dependence, long scan time or inability to handle the large B1 inhomogeneity that occurs even across the human brain at 7T. The Bloch-Siegert B1 mapping method has been recently introduce...
متن کاملApproximate Fourier domain expression for Bloch-Siegert shift.
PURPOSE In this study, a new simple Fourier domain-based analytical expression for the Bloch-Siegert (BS) shift-based B1 mapping method is proposed to obtain |B1+| more accurately while using short BS pulse durations and small off-resonance frequencies. THEORY AND METHODS A new simple analytical expression for the BS shift is derived by simplifying the Bloch equations. In this expression, the...
متن کاملBloch‐Siegert B1+‐mapping for human cardiac 31P‐MRS at 7 Tesla
PURPOSE Phosphorus MR spectroscopy ((31) P-MRS) is a powerful tool for investigating tissue energetics in vivo. Cardiac (31) P-MRS is typically performed using surface coils that create an inhomogeneous excitation field across the myocardium. Accurate measurements of B1+ (and hence flip angle) are necessary for quantitative analysis of (31) P-MR spectra. We demonstrate a Bloch-Siegert B1+-mappi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 63 5 شماره
صفحات -
تاریخ انتشار 2010