Left mainstem bronchus rupture due to a left-sided double lumen tube.

نویسندگان

  • E Cools
  • A P Neyrinck
چکیده

Double lumen tubes (DLT) are a cornerstone in thoracic anaesthesia to achieve onelung ventilation. Due to the shape and size of these devices, airway injuries might occur. The reported incidence of tracheobronchial ruptures caused by a DLT is very low (0.005% for single-lumen tubes and 0.05% for double-lumen intubations), but the outcome can be life-threatening (1, 2). In the past, treatment of tracheobronchial ruptures was performed surgically, nowadays conservative treatment can be considered (3, 4). Here, we report a case of tracheobronchial rupture during oesophageal surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left mainstem bronchial rupture during one-lung ventilation with Robertshaw double lumen endobronchial tube -A case report-

Lung separation using a double-lumen endobronchial tube is necessary for video assisted thoracoscopy (VATs). Bronchial rupture after intubation with a double-lumen endobronchial tube has been rarely reported. We report a case of a 70-year-old man who had solitary pulmonary nodule in his right upper lobe. He was intubated with a left-sided Robertshaw double-lumen endobronchial tube. He underwent...

متن کامل

Misplacement of left-sided double-lumen tubes into the right mainstem bronchus: incidence, risk factors and blind repositioning techniques

BACKGROUND Double-lumen endobronchial tubes (DLTs) are commonly advanced into the mainstem bronchus either blindly or by fiberoptic bronchoscopic guidance. However, blind advancement may result in misplacement of left-sided DLTs into the right bronchus. Therefore, incidence, risk factors, and blind repositioning techniques for right bronchial misplacement of left-sided DLTs were investigated. ...

متن کامل

The height-based formula for prediction of left-sided double-lumen tracheal tube depth.

In the commonly used double-lumen tube (DLT) intubation procedure, the tip of a DLT is inserted into the mainstem bronchus in a blind fashion, followed by determination of precise DLT position by a fiberoptic bronchoscope. Several studies have suggested that insertion depth for a left-sided DLT is correlated with physical factors including height and neck length.1-3 However, there are no widely...

متن کامل

Incidental left main bronchus obstruction during left-sided double-lumen tube intubation of a patient with an unrecognized tracheal bronchus

INTRODUCTION Tracheal bronchus is a right-sided anomalous bronchus arising from the trachea above the main carina and occurs in 0.1% to 2% of the general population. CASE PRESENTATION We present a case of left main bronchus obstruction during a left-sided double-lumen tube intubation in a patient with an unrecognized tracheal bronchus. After the intubation, to confirm the position of the tube...

متن کامل

تعیین موقعیت لوله‌های تراشه دابل لومن در جراحی توراکس: کمپلیانس بگ در مقایسه با برونکوسکوپ فیبراوپتیک

Background: Lung separation is the basis of thoracic anesthesia, which is performed by different instruments. Checking probable malpositioning of tracheal tube needs fiberoptic bronchoscopy. The aim of this study was to compare respirator suggested compliance with fiberoptic findings in detecting major tracheal tube malpositioning.Methods: A total of 256 patients undergoing thoracic surgery wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta anaesthesiologica Belgica

دوره 66 4  شماره 

صفحات  -

تاریخ انتشار 2015