Does parallel item content on WOMAC's Pain and Function Subscales limit its ability to detect change in functional status?
نویسندگان
چکیده
BACKGROUND Although the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) is considered the leading outcome measure for patients with osteoarthritis of the lower extremity, recent work has challenged its factorial validity and the physical function subscale's ability to detect valid change when pain and function display different profiles of change. This study examined the etiology of the WOMAC's physical function subscale's limited ability to detect change in the presence of discordant changes for pain and function. We hypothesized that the duplication of some items on the WOMAC's pain and function subscales contributed to this shortcoming. METHODS Two eight-item physical function scales were abstracted from the WOMAC's 17-item physical function subscale: one contained activities and themes that were duplicated on the pain subscale (SIMILAR-8); the other version avoided overlapping activities (DISSIMILAR-8). Factorial validity of the shortened measures was assessed on 310 patients awaiting hip or knee arthroplasty. The shortened measures' abilities to detect change were examined on a sample of 104 patients following primary hip or knee arthroplasty. The WOMAC and three performance measures that included activity specific pain assessments--40 m walk test, stair test, and timed-up-and-go test--were administered preoperatively, within 16 days of hip or knee arthroplasty, and at an interval of greater than 20 days following the first post-surgical assessment. Standardized response means were used to quantify change. RESULTS The SIMILAR-8 did not demonstrate factorial validity; however, the factorial structure of the DISSIMILAR-8 was supported. The time to complete the performance measures more than doubled between the preoperative and first postoperative assessments supporting the theory that lower extremity functional status diminished over this interval. The DISSIMILAR-8 detected this deterioration in functional status; however, no significant change was noted for the SIMILAR-8. The WOMAC pain scale demonstrated a slight reduction in pain and the performance specific pain measures did not reflect a change in pain. All measures showed substantial improvement over the second assessment interval. CONCLUSIONS These findings support the hypothesis that activity overlap on the pain and function subscales plays a causal role in limiting the WOMAC physical function subscale's ability to detect change.
منابع مشابه
The Effect of Alendronate on Symptoms of Knee Osteoarthritis: A Randomized Controlled Trial
Background: Knee osteoarthritis is a common degenerative joint disorder and a major cause of pain and disability. Recent studies have suggested that bisphosphonates such as alendronate may have a role in the treatment of osteoarthritis. The purpose of the present study was to investigate the potential effect of alendronate on the symptoms of knee osteoarthritis. Methods: Thirty nine patients wi...
متن کاملComparison of the responsiveness of the Foot Health Status Questionnaire and the Manchester Foot Pain and Disability Index in older people
BACKGROUND In recent years, several questionnaires have been developed for the assessment of foot health and its impact on quality of life. In order for these tools to be useful outcome measures in clinical trials, their ability to detect change over time (responsiveness) needs to be determined. Therefore, the aim of this study was to assess the responsiveness of two commonly-used questionnaire...
متن کاملDevelopment and validation of the patient-rated ulnar nerve evaluation
BACKGROUND Compression neuropathy at the elbow causes substantial pain and disability. Clinical research on this disorder is hampered by the lack of a specific outcome measure for this problem. A patient-reported outcome measure, The Patient-Rated Ulnar Nerve Evaluation (PRUNE) was developed to assess pain, symptoms and functional disability in patients with ulnar nerve compression at the elbow...
متن کاملEvidence of validity for the Foot and Ankle Ability Measure (FAAM).
BACKGROUND There is no universally accepted instrument that can be used to evaluate changes in self-reported physical function for individuals with leg, ankle, and foot musculoskeletal disorders. The objective of this study was to develop an instrument to meet this need: the Foot and Ankle Ability Measure (FAAM). Additionally, this study was designed to provide validity evidence for interpretat...
متن کاملPsychometric properties of the pain stages of change questionnaire as evaluated by rasch analysis in patients with chronic musculoskeletal pain
BACKGROUND Our objective was to evaluate the measurement properties of the Pain Stages of Change Questionnaire (PSOCQ) and its four subscales Precontemplation, Contemplation, Action and Maintenance. METHODS A total of 231 patients, median age 42 years, with chronic musculoskeletal pain responded to the 30 items in PSOCQ. Thresholds for item scores, and unidimensionality and invariance of the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- BMC Musculoskeletal Disorders
دوره 5 شماره
صفحات -