Applicability improvement and hysteresis current control method simplification in shunt active filters

Hysteresis current control method is vastly used in PWM inverters because of simplicity in performance, fast control response and good ability in limiting peak current. However, switching frequency in hysteresis current control method with fixed bandwidth has large variation during a cycle and therefore causes non-optimal current ripple generation in output current. One of basic problems in imp...

متن کامل

Performance Scrutiny of Two Control Schemes Based on DSM and HB in Active Power Filter

This paper presents a comparative analysis between two current control strategies, constant source power and generalized Fryze current, used in Active Power Filter (APF) applications having three different modulation methods. The Hysteresis Band (HB) and first-order Delta-Sigma Modulation (DSM) as well as the second-order DSM is applied. The power section of the active power filter is viewed as...

متن کامل

Adaptive Modified Minimally Switched Hysteresis Controlled Shunt Active Power Filter for Harmonic Mitigation

The main focus of this article is to investigate the effects of Adaptive control on the switching frequency and Total Harmonic Distortion of a modified, minimally switched hysteresis controlled shunt active power filter. Reference current generation was done using Instantaneous real and reactive power algorithm. Pulses to the minimally switched grid interactive inverter in which only two switch...

متن کامل

New Hysteresis Control Method for Three Phase Shunt Active Power Filter

The quality of the current waveform generated by a current controlled, voltage source shunt active power filter depends basically on three factors: (i) The reference signal being generated; (ii) the modulation method used and (iii) the switching frequency of the PWM modulator. A new adaptive hysteresis band modulation method is proposed. In this paper, the periodical sampling constant hysteresi...

متن کامل

Mitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach

This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...

متن کامل