Legionnaires’ Disease Caused by Legionella pneumophila Serogroups 5 and 10, China

نویسندگان

  • Qi Zhang
  • Haijian Zhou
  • Rong Chen
  • Tian Qin
  • Hongyu Ren
  • Bin Liu
  • Xinliang Ding
  • Dan Sha
  • Weijie Zhou
چکیده

To the Editor: Legionnaires’ disease is a systemic infection caused by gram-negative bacteria belonging to the genus Legionella. The primary clinical manifestation is pneumonia. Legionella spp. are typically found in natural and artificially hydrated environments. Legionella pneumophila is the species responsible for ≈90% of human cases of infection. L. pneumophila is divided into 15 serogroups, among which serogroup 1 is the most prevalent disease-causing variant (1). In contrast, rare cases are caused by other serogroups. We describe a case of Legionnaires’ disease caused by co-infection with L. pneumophila serogroups 5 and 10 and the genotype characteristics of these strains. The case-patient was a 77-yearold man who had chronic hepatitis B for 50 years, ankylosing spondylitis for 40 years, and chronic cholecystitis for 5 years. On September 17, 2012, he was admitted to Wuxi People’s Hospital (Wuxi, China) for treatment after a continuous cough for 15 days and a high fever for 2 days. At admission, the patient had a blood pressure of 130/65 mm Hg, a pulse rate of 102 beats/minute, and a body temperature of 37.4°C, which increased to 38.4°C four hours later. Laboratory tests showed a leukocyte count of 9,200 cells/μL (88.7% neutrophils) and a C-reactive protein level of 31 mg/L in serum. Lung inflammation was identified by computed tomography. The result of a urinary antigen test for L. pneumophila serogroup 1 (Binax, Portland, ME, USA) was negative. Bronchoalveolar lavage was performed, and fluid was collected for bacterial culture and molecular analysis. Real-time PCRs were performed with primers specific for the 5S rRNA gene of the genus Legionella (2) and the L. pneumophila-specific mip gene (3). Legionella colonies isolated from bronchoalveolar lavage fluid grew on buffered-charcoal yeast extract agar. Nine Legionella-like colonies were isolated, and all showed positive results by PCRs. The colonies were identified as L. pneumophila serogroups 2–14 by using the Legionella latex test (Oxoid, Basingstoke, UK). Among these colonies, 5 were identified as L. pneumophila serogroup 5, and 4 were identified as serogroup 10 by using a monoclonal antibody (Denka Seiken, Tokyo, Japan). Environmental investigations were conducted in the patient’s house and hospital room, but L. pneumophila serogroup 5 and 10 were not detected in any of the locations tested. Pulsed-field gel electrophoresis (PFGE) (4) was used to investigate the 9 L. pneumophila strains. Two PFGE patterns that were 94% similar were observed; each pattern represented 1 serogroup. The PFGE patterns were compared with those of a reference database of L. pneumophila for China. All L. pneumophila in the database, including 41 strains isolated from the city in which the patient resided in 2012, had patterns different from those of the 9 strains. Two clinical L. pneumophila strains of different serogroups were further analyzed by sequence typing (5,6). Sequence type (ST) indicated that allele numbers for flaA, pilE, asd, mip, mompS, proA, and neuA genes were 6, 10, 15, 28, 21, 7, and 207 for serogroup 5 strains and 6, 10, 15, 10, 21, 40, and 207 for serogroup 10 strains. By querying the ST database for L. pneumophila (http:// www.ewgli.org), we found that both profiles were new and assigned these 2 strains the numbers ST1440 (serogroup 5) and ST1439 (serogroup 10). STs of these 2 isolates differed from each other by only 2 alleles (3 nt in the mip gene and 1 nt in the proA gene), which suggested that the isolates might be more closely related to each other than suggested by serologic analysis. Human infections with L. pneumophila serogroups 5 and 10 have been rarely reported (1,7). Our study confirms human infection with 2 L. pneumophila serogroups that did not involve serogroup 1. Results for this case-patient also indicated that a negative urinary antigen test result should not be a reason for ruling out Legionnaires’ disease because the urinary antigen kit used detects only L. pneumophila serogroup 1 antigen. L. pneumophila serogroups 5 and 10 are probably underrecognized pathogenic serogroups. Culture and molecular analysis should be performed to obtain an accurate diagnosis. Rare co-infections with L. pneumophila serogroup strains have been identified by culture methods (8,9). The cases reported previously and in this study indicate that co-infections with different serogroups are more common than currently recognized and that multiple colonies should be

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isolation of Legionella Pneumophila Serogroups 1, 8 & 10 (Causative Agents of Legionnaires\' Disease) from Water Sources in Tehran, Iran

In this survey, 187 samples collected from 9 different sources of water in Tehran such as: water cool‌ers, neonates incubators, water bathes (37° C), little pools in parks or squares, cooling towers, hot or cold water taps, were examined for Legionnaires' disease agents. Inoculating water samples on selec‌tive and nonselective media resulted in isolation of several strains of gram negative bact...

متن کامل

Evaluation of the Binax and Biotest urinary antigen kits for detection of Legionnaires' disease due to multiple serogroups and species of Legionella.

The Binax and the Biotest urinary antigen kits for the detection of Legionnaires' disease caused by organisms other than Legionella pneumophila were compared by testing 45 urine samples from non-Legionella pneumophila serogroup 1 patients previously positive in a broad-spectrum enzyme-linked immunosorbent assay (ELISA). Eighteen were positive with the Binax kit, and 13 were positive with the Bi...

متن کامل

Two Legionnaires' disease cases associated with industrial waste water treatment plants: a case report

BACKGROUND Finnish and Swedish waste water systems used by the forest industry were found to be exceptionally heavily contaminated with legionellae in 2005. CASE PRESENTATION We report two cases of severe pneumonia in employees working at two separate mills in Finland in 2006. Legionella serological and urinary antigen tests were used to diagnose Legionnaires' disease in the symptomatic emplo...

متن کامل

Environmental survey of Legionella pneumophila in hot springs in Taiwan.

Acquisition of sporadic community-acquired legionnaires' disease has been linked to hot springs and whirlpool baths. Outbreaks of hot spring-associated legionnaires' disease were reported in Japan in the last few years. Although the mode of transmission is unclear, the presence of Legionella in hot springs may discourage hot springs resort visits by the general public. An environmental survey w...

متن کامل

Outbreak of Legionnaire’s Disease Caused by Legionella pneumophila Serogroups 1 and 13

In Japan, hot springs and public baths are the major sources of legionellosis. In 2015, an outbreak of Legionnaires' disease occurred among 7 patients who had visited a spa house. Laboratory investigation indicated that L. pneumophila serogroup 1 and 13 strains caused the outbreak and that these strains were genetically related.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2014