Adverse sequelae following revision of a total hip replacement for a fractured ceramic component: case report

نویسندگان

  • Ling Hong Lee
  • David Langton
  • Stephen Green
چکیده

Revision total hip replacement following a fractured ceramic bearing component presents a challenge in the choice of the new bearing implant. A femoral head made of equal or harder material should be implanted to prevent catastrophic wear. Despite this, patients and surgeons must be wary of potential complications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature

Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...

متن کامل

Hip Arthroplasty and its Revision in a Child: Case Report and Literature Review

Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...

متن کامل

Fatal Cobalt Toxicity after a Non-Metal-on-Metal Total Hip Arthroplasty

This case illustrates the potential for systemic cobalt toxicity in non-metal-on-metal bearings and its potentially devastating consequences. We present a 71-year-old male with grinding sensations in his right hip following ceramic-on-ceramic total hip arthroplasty (THA). After diagnosing a fractured ceramic liner, the hip prosthesis was revised into a metal-on-polyethylene bearing. At one year...

متن کامل

Adverse local tissue reaction after 2 revision hip replacements for ceramic liner fracture

INTRODUCTION In younger patients, ceramic-on-ceramic (CoC) bearing surfaces are usually recommended for total hip replacement (THR) because of their low wear rate and longer expected functional life. Although technical advancements have reduced the risk of ceramic bearings fracture, this complication remains a major concern. CASE DESCRIPTION We present the case of a 56-year-old patient underg...

متن کامل

Cobalt Intoxication Heart Failure after Revision Total Hip Replacement for Ceramic Head Fracture: A Case Report

In 1960s, toxic heart failure due to cobalt poisoning was firstly reported from Canadian industrial worker. Following development of bearing materials in hip arthroplasties, using cobalt-chrome alloy in bearing surface, there were rarely reported of systemic affect toxic cobaltism include toxic heart failure due to articulation wear in Western countries. It could be happened more easily by thir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2015