A comparative study on the accuracy of the devices for measuring the implant stability

نویسندگان

  • In-Ho Cho
  • Young-Il Lee
  • Young-Mi Kim
چکیده

STATEMENT OF PROBLEM How the ISQ values measured by Osstell™ and Osstell™ Mentor are related, and whether the ISQ values acquired from the two machines changes in accordance with changes in implant stability are not yet fully understood. PURPOSE The aim of this study was to find out correlation between the ISQ values acquired from Osstell™ and Osstell™ Mentor, and to evaluate the clinical effectiveness and accuracy of two devices. MATERIAL AND METHODS Sixty two implants were inserted into 47 patients, and their ISQ values were measured using Osstell™ and Osstell™ Mentor. In the first stage surgery, the ISQ values of forty four implants inserted into thirty five patients were measured. In the second stage surgery, the values of fifty implants inserted into thirty seven patients were measured. The values were analyzed to determine the difference between the mean ISQ values of Osstell™ and Osstell™ Mentor. In addition, the correlation between implants used in the first and second stage of surgery with regard to their types and areas of insertion were analyzed. The difference between the ISQ values of 32 implants in each patient during the first and second stage was analyzed. The statistical assessment was carried out using SPSS V. 12.0 for Win. (SPSS Inc., Chicago, USA). The Pearson correlation coefficient was used to examine the correlation between Osstell™ and Osstell™ Mentor in the first and second stages of surgery, whereas the difference between their ISQ values was evaluated using a paired t-test. RESULTS In the first stage, the mean ISQ value for Osstell™ and Osstell™ Mentor was 70.84 and 75.09, respectively, showing a significant difference (P < .01). In the second stage, the mean ISQ value of Osstell™ and Osstell™ Mentor was 71.76 and 75.94, respectively, also showing a significant difference (P < .01). The difference between the ISQ values in patients in the first and the second stages was significant with both instruments. CONCLUSION The significant difference in the values obtained using the Osstell™ and Osstell™ Mentor between the first and second stages of implant surgery indicates that these values can be a convenient and precise way for evaluating the implant stability in clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Study of the Effect of Storage Environment Temperature on the Accuracy of Hygedent and Chromogel Alginate Impression Materials

Background and Aim: Considering the lack of sufficient and even contradictory studies on the effect of temperature-dependent dimensional changes of alginate before pouring, this study aimed to investigate the effect of storage temperature of Hygedent and Chromogel alginate molds on dimensional stability.  Materials and Methods: In this in-vitro experimental study, dimensional changes of two t...

متن کامل

Evaluation of Panoramic Radiography Accuracy in Estimating the Crestal Width of Dental Implant in Different Jaw Regions

Introduction: The aim of this study was to determine the accuracy of digital panoramic radiography in estimating the crestal width of implant fixtures after surgery. Materials and Methods:We selected 241 digital panoramic images after implant insertion which had documented information of their actual size. The crestal width was measured on radiographs. We compared two measuring methods in diff...

متن کامل

Improving Vehicular Ad-Hoc Network Stability Using Meta-Heuristic Algorithms

Vehicular ad-hoc network (VANET) is an important component of intelligent transportation systems, in which vehicles are equipped with on-board computing and communication devices which enable vehicle-to-vehicle communication. Consequently, with regard to larger communication due to the greater number of vehicles, stability of connectivity would be a challenging problem. Clustering technique as ...

متن کامل

بررسی مقایسه‌ای دو سیستم Cone Beam CT به لحاظ دقت اندازه‌گیری خطی محل‌های قراردهی ایمپلنت در مندیبل به‌صورت In Vitro

Background and Objective: There are critical areas in the mandible that should be considered during implant placement such as inferior alveolar canal, mental foramen, and the root of the adjacent tooth. Two-dimensional images obtained from periapical, panoramic, and conventional tomography are considered in the evaluation of implant placement and bone quality. Cone-beam computed tomography (CBC...

متن کامل

تعیین دقت ثبت ایمپلنت و جزئیات سطحی با استفاده از پلی‌اتر و پلی‌وینیل سایلوکسان با روش تری بسته

  Background and Aims: Making accurate impressions of prepared teeth when they are adjacent to dental implants is of great importance. In these situations, disregarding the selection of appropriate impression material and technique, not only can affect accuracy of transferring of the 3-dimentional spatial status of implant, but also can jeopardize the accurate recording of tooth. In the present...

متن کامل

Comparison of Implant Stability in Sinus Lift Surgery Using Autogenous Versus Allogeneic Bone Grafts

Background and aim: The most common method of increasing implant stability in the posterior maxilla comprises the reinforcement of bone height using bone grafts in sinus lift surgery. The purpose of the present study was to compare autogenous and allogeneic bone grafts in implant stability after open sinus lift surgery. Materials and methods: This split-mouth clinical trial compared the implant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2009