Letter by Lumley et al regarding article, "arterial pulse wave dynamics after percutaneous aortic valve replacement: fall in coronary diastolic suction with increasing heart rate as a basis for angina symptoms in aortic stenosis".

نویسندگان

  • Matthew Lumley
  • Kalpa De Silva
  • Divaka Perera
چکیده

in Aortic Stenosis " 1 with great interest and would like to commend the authors for producing novel coronary wave intensity data in the aortic stenosis population. The microcirculatory decompression (suction) wave was reported to increase in proportion to the severity of aortic stenosis (rϭ0.59, Pϭ0.05), a change opposite to that which was reported previously by the same authors in patients with left ventricular hypertrophy. 2 The severity of aortic stenosis in determining this relationship was judged by peak aortic gradient. The 11 patients included in the study had an aortic valve area of 0.6Ϯ0.1 cm 2 , suggesting a relatively homogeneous population with respect to aortic valve area. In contrast, a broad range of peak valve gradients was observed (81Ϯ24 mm Hg), which would be consistent with a range of left ventricular (LV) systolic function. It is therefore possible that the peak aortic gradient is a surrogate measure of LV function in this cohort, most of whom had an aortic valve area Ͻ0.8 cm 2 (2 SD above the mean). In this context, the magnitude of the microcirculatory decompression wave may, in fact, be a reflection of LV systolic and diastolic function rather than aortic stenosis per se. The authors state in their article that the extent of microcirculatory compression during systole is related to the rate and magnitude of decompression (recoil) in diastole. Hence, compared to those with impaired LV function, patients with preserved function would be expected to have greater systolic microcirculatory compression and consequently more pronounced recoil, leading to an increased microcirculatory decompression–associated wave energy. Given that simultaneous pressure and Doppler velocity were measured in the left main coronary artery rather than the left anterior descending or circumflex vessel, it would be surprising if septal and posterior wall thickening (individually or collectively) were found to correlate with the amplitude of the microcirculatory decompression wave. On the other hand, it would be interesting to assess the relationship between the left main coronary artery backward decom-pression wave and global LV function (as assessed by LV ejection fraction or LV outflow tract–velocity-time integral) in this study cohort. Similarly, it may be instructive to assess the relationship between this wave and indices of aortic stenosis, which are least dependent on LV function, such as aortic valve area. Percutaneous aortic valve replacement is an innovative model for assessing the impact of aortic stenosis and of relieving the valve stenosis. However, the …

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Valvular Heart Disease Arterial Pulse Wave Dynamics After Percutaneous Aortic Valve Replacement Fall in Coronary Diastolic Suction With Increasing Heart Rate as a Basis for Angina Symptoms in Aortic Stenosis

Background—Aortic stenosis causes angina despite unobstructed arteries. Measurement of conventional coronary hemodynamic parameters in patients undergoing valvular surgery has failed to explain these symptoms. With the advent of percutaneous aortic valve replacement (PAVR) and developments in coronary pulse wave analysis, it is now possible to instantaneously abolish the valvular stenosis and t...

متن کامل

Arterial pulse wave dynamics after percutaneous aortic valve replacement: fall in coronary diastolic suction with increasing heart rate as a basis for angina symptoms in aortic stenosis.

BACKGROUND Aortic stenosis causes angina despite unobstructed arteries. Measurement of conventional coronary hemodynamic parameters in patients undergoing valvular surgery has failed to explain these symptoms. With the advent of percutaneous aortic valve replacement (PAVR) and developments in coronary pulse wave analysis, it is now possible to instantaneously abolish the valvular stenosis and t...

متن کامل

Changing reflections of the coronary microcirculation after percutaneous aortic valve replacement: novel observations with arterial pulsed wave dynamics.

One cannot help but be intrigued by the novel physiological insights that pulsed wave analysis brings to one of the oldest cardiovascular diseases, AS, and one of the newest procedures in interventional cardiology, namely PAVR. For decades, the diagnosis and treatment of AS have rightly focused on identifying and then ameliorating the adverse consequences of abnormal transvalvular pressure and ...

متن کامل

Iatrogenic left anterior descending artery stenosis early after aortic valve replacement presenting with T-wave-pseudonormalization - a case report

BACKGROUND Both iatrogenic coronary artery stenosis early after aortic valve replacement and pseudonormalization of inverted T-waves in acute ischemia are rare but well-recognized findings which coincide in this case. CASE PRESENTATION 10 weeks after aortic valve replacement, a 58-year-old male patient was readmitted with recent onset of unstable angina pectoris. Electrocardiography showed in...

متن کامل

A new option for the treatment of aortic stenosis: percutaneous aortic valve replacement.

http://ccn.aacnjournals.org higher in men than in women. Increasing evidence indicates that the disease is accelerated by the same factors that affect coronary artery disease, including smoking, hypercholesterolemia, hyper tension, and diabetes. Until now, surgical valve replacement, pioneered in the 1960s with mechanical or tissue prostheses, was the only effective treatment available to allev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 125 16  شماره 

صفحات  -

تاریخ انتشار 2012