Fast Monte Carlo simulation of DNA damage formed by electrons and light ions.

نویسندگان

  • V A Semenenko
  • R D Stewart
چکیده

The passage of ionizing radiation through living organisms initiates physical and chemical processes that create clusters of damaged nucleotides within one or two turns of the DNA. These clusters are widely considered an important initiating event for the induction of other biological endpoints, including cell killing and neoplastic transformation. Monte Carlo simulations of the DNA damage formation process are a useful adjunct to experiments because they provide additional information about the spatial configuration of damage within a cluster. In this paper, the fast Monte Carlo damage simulation (MCDS) algorithm is re-parameterized so that yields of double-strand breaks, single-strand breaks and sites of multiple base damage can be simulated for electrons, protons and alpha particles with kinetic energies on the order of GeV. The MCDS algorithm provides a useful, quasi-phenomenological scheme to interpolate damage yields from computationally expensive, but more detailed, track-structure simulations. The predicted characteristics of various classes of damage produced by electrons, protons and alpha particles, such as average number of lesions per DNA damage cluster and cluster length in base pairs, are presented. A study examining the effects on damage complexity of an extrinsic free radical scavenger, dimethyl sulfoxide, is also presented. The reported studies provide new information that will aid efforts to characterize the relative biological effectiveness of high-energy protons and other light ions, which are sometimes used in particle therapy for the treatment of cancer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Developing a software for simulation of gaseous detectors with Monte carlo method in c++ programming language

In this paper we consider a gaseous detector and supposed, because of pass of an ionizing radiation, an electron created inside it. By numerical simulation with monte carlo method and concluding the impacts, scatterings and creation of secondary electrons, we find the trajectory of initial and secondary electrons. Dependence of number of secondary electrons to applied electrical field is invest...

متن کامل

The Role of High-Energy Ion-Atom/Molecule Collisions in Radiotherapy

The need for ions in radiotherapy stems from the most favorable localization of the largest energy deposition, precisely at the tumor site with small energy losses away from the target. Such a dose conformity to the target is due to heavy masses of ions that scatter predominantly in the forward direction and lose maximal energy mainly near the end of their path in the vicinity of the Bragg peak...

متن کامل

Evaluation of Electron Contamination in Cancer Treatment with Megavoltage Photon Beams: Monte Carlo Study

Background: Megavoltage beams used in radiotherapy are contaminated with secondary electrons. Different parts of linac head and air above patient act as a source of this contamination. This contamination can increase damage to skin and subcutaneous tissue during radiotherapy. Monte Carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...

متن کامل

Monte Carlo Simulation of Multiplication Factor in PIN In0.52Al0.48As Avalanche Photodiodes

In this paper, we calculate electron and hole impactionization coefficients in In0.52Al0.48As using a Monte Carlo modelwhich has two valleys and two bands for electrons and holesrespectively. Also, we calculate multiplication factor for electronand hole initiated multiplication regimes and breakdown voltagein In0.52Al0.48As PIN avalanche photodiodes. To validate themodel, we compare our simulat...

متن کامل

Assessment of Effect Technical Directional Bremsstrahlung Splitting (DBS) on Spectra and Parameters of Simulation with Monte carlo Method BEAMnrc Code (Study Monte Carlo)

Introduction: Previous studies have shown that a Monte Carlo method for the transportations photon beam in medical linear accelerator is a good way. Strip of simulation can be used to measure the dose distribution in phantoms and patients' body. EGSnrc Code is the only code written for use in the field of radiation therapy that has many subset codes that BEAMnrc code is an impo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 51 7  شماره 

صفحات  -

تاریخ انتشار 2006