Precise placement of multiple electrodes into functionally predefined cortical locations.

نویسندگان

  • Michael Niessing
  • Kerstin Schmidt
  • Wolf Singer
  • Ralf Galuske
چکیده

Current research on topics such as effective connectivity, neuronal coding strategy or signal propagation in the central nervous system requires simultaneous recordings from multiple sites within functionally grouped but topologically distributed neuronal clusters. We have addressed this issue by characterization of the cortical functional architecture using optical imaging of intrinsic signals (OI) and subsequent placement of multiple, individually adjustable electrodes into pre-selected domains. In order to achieve maximum precision and flexibility for the positioning of electrodes, a plastic cylinder containing channels of an extremely high aspect ratio (density >20 channels/mm(2)) was fixed above the cortex and individual channel positions were superimposed onto the functional maps of orientation columns obtained previously with OI. Subsequently, channels corresponding to the desired locations in the functional map were used as guide tubes for electrode insertion. The spatial precision of this approach was in the range of 100 microm and experiments in cat primary visual cortex revealed a close correlation between the desired and the actually recorded orientation preferences of the targeted columns. The method is applicable to all cortical areas in which OI is feasible and offers a high degree of flexibility with respect to the number and geometry of applicable probes. It is, thus, an excellent tool for studying distributed codes and interactions between multiple predefined recording sites.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantative Evaluation of the Efficiency of Facial Bio-potential Signals Based on Forehead Three-Channel Electrode Placement For Facial Gesture Recognition Applicable in a Human-Machine Interface

Introduction: Today, facial bio-potential signals are employed in many human-machine interface applications for enhancing and empowering the rehabilitation process. The main point to achieve that goal is to record appropriate bioelectric signals from the human face by placing and configuring electrodes over it in the right way. In this paper, heuristic geometrical position and configuration of ...

متن کامل

Magnetic resonance image-guided implantation of chronic recording electrodes in the macaque intraparietal sulcus.

The implantation of chronic recording electrodes in the brain has been shown to be a valuable method for simultaneously recording from many neurons. However, precise placement of these electrodes, crucial for successful recording, is challenging if the target area is not on the brain surface. Here we present a stereotaxic implantation procedure to chronically implant bundles of recording electr...

متن کامل

Discriminability of Single and Multichannel Intracortical Microstimulation within Somatosensory Cortex

The addition of tactile and proprioceptive feedback to neuroprosthetic limbs is expected to significantly improve the control of these devices. Intracortical microstimulation (ICMS) of somatosensory cortex is a promising method of delivering this sensory feedback. To date, the main focus of somatosensory ICMS studies has been to deliver discriminable signals, corresponding to varying intensity,...

متن کامل

Selectivity of audiovisual ECoG responses revealed under naturalistic stimuli in the human cortex.

A fundamental debate in the study of cortical sensory systems concerns the scale of functional selectivity in cortical networks. Brain imaging studies have repeatedly demonstrated functional selectivity in entire cortical areas and networks using predetermined stimuli. However, it is not clear to what extent these networks are heterogeneous, i.e., whether the selectivity profiles in subregions ...

متن کامل

Intraoperative neurophysiologic mapping of the central cortical region for epidural electrode placement in the treatment of neuropathic pain by motor cortex stimulation.

Neuropathic pain results from injury to the central or peripheral nervous system and can prove itself refractory to classical medical treatment by anticonvulsants and antidepressants. In such cases, motor cortex stimulation is among the neurostimulation techniques available for its symptomatic control. This technique is based on surgical implantation of electrodes over the motor cortical repres...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of neuroscience methods

دوره 126 2  شماره 

صفحات  -

تاریخ انتشار 2003