Double-Difference Tomography: The Method and Its Application to the Hayward Fault, California
نویسندگان
چکیده
We have developed a double-difference (DD) seismic tomography method that makes use of both absolute and relative arrival times. By reducing systematic errors using the more accurate relative arrival times, the method produces an improved velocity model. Simultaneously, it yields event locations of a quality equivalent to those of the DD location method, while avoiding simplifying assumptions of that method. We test this method on a synthetic dataset and find that it produces a more accurate velocity model and event locations than standard tomography. We also test this method on a Hayward fault, California, earthquake dataset spanning 1984–1998. The earthquakes relocated by this method collapse to a thin line along the fault trace, consistent with previous results. The DD velocity model has sharper velocity contrasts near the source region than the standard tomography model.
منابع مشابه
A Double-Difference Earthquake Location Algorithm: Method and Application to the Northern Hayward Fault, California
We have developed an efficient method to determine high-resolution hypocenter locations over large distances. The location method incorporates ordinary absolute travel-time measurements and/or cross-correlation P-and S-wave differential travel-time measurements. Residuals between observed and theoretical travel-time differences (or double-differences) are minimized for pairs of earthquakes at e...
متن کاملFault structure and mechanics of the Hayward Fault, California, from doubledifference earthquake locations
[1] The relationship between small-magnitude seismicity and large-scale crustal faulting along the Hayward Fault, California, is investigated using a double-difference (DD) earthquake location algorithm. We used the DD method to determine high-resolution hypocenter locations of the seismicity that occurred between 1967 and 1998. The DD technique incorporates catalog travel time data and relativ...
متن کاملDouble phase fault location in microgrids with the presence of electric vehicles and Distributed parameters line model
Nowadays, renewable energy is increasingly used in smart grids and microgrids to reduce the use of fossil fuels and improve network efficiency. Like all power system devices, microgrids are subject to transient and steady-state faults, such as short circuits. These faults impair reliability and consumer dissatisfaction. To accurately, automatically, and economically determine the location of a ...
متن کاملFault Detection and Classification in Double-Circuit Transmission Line in Presence of TCSC Using Hybrid Intelligent Method
In this paper, an effective method for fault detection and classification in a double-circuit transmission line compensated with TCSC is proposed. The mutual coupling of parallel transmission lines and presence of TCSC affect the frequency content of the input signal of a distance relay and hence fault detection and fault classification face some challenges. One of the most effective methods fo...
متن کاملYield, Leaf Mineral Content, and Quality Properties of Hayward kiwifruit as Influenced by Different Fertilization Methods
Kiwifruit requires a high quantity of nutrients that must be supplied through fertilization to obtain an optimum yield on a sustainable basis. This research was conducted to evaluate different fertilization methods including broadcast application (as control), deep placement of the fertilizer and fertigation, alone or in combination with foliar application and their effects on the yield, leaf m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2003