Effect of pressure and padding on motion artifact of textile electrodes

نویسندگان

  • Alper Cömert
  • Markku Honkala
  • Jari Hyttinen
چکیده

BACKGROUND With the aging population and rising healthcare costs, wearable monitoring is gaining importance. The motion artifact affecting dry electrodes is one of the main challenges preventing the widespread use of wearable monitoring systems. In this paper we investigate the motion artifact and ways of making a textile electrode more resilient against motion artifact. Our aim is to study the effects of the pressure exerted onto the electrode, and the effects of inserting padding between the applied pressure and the electrode. METHOD We measure real time electrode-skin interface impedance, ECG from two channels, the motion artifact related surface potential, and exerted pressure during controlled motion by a measurement setup designed to estimate the relation of motion artifact to the signals. We use different foam padding materials with various mechanical properties and apply electrode pressures between 5 and 25 mmHg to understand their effect. A QRS and noise detection algorithm based on a modified Pan-Tompkins QRS detection algorithm estimates the electrode behaviour in respect to the motion artifact from two channels; one dominated by the motion artifact and one containing both the motion artifact and the ECG. This procedure enables us to quantify a given setup's susceptibility to the motion artifact. RESULTS Pressure is found to strongly affect signal quality as is the use of padding. In general, the paddings reduce the motion artifact. However the shape and frequency components of the motion artifact vary for different paddings, and their material and physical properties. Electrode impedance at 100 kHz correlates in some cases with the motion artifact but it is not a good predictor of the motion artifact. CONCLUSION From the results of this study, guidelines for improving electrode design regarding padding and pressure can be formulated as paddings are a necessary part of the system for reducing the motion artifact, and further, their effect maximises between 15 mmHg and 20 mmHg of exerted pressure. In addition, we present new methods for evaluating electrode sensitivity to motion, utilizing the detection of noise peaks that fall into the same frequency band as R-peaks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the possible effect of electrode support structure on motion artifact in wearable bioelectric signal monitoring

BACKGROUND With advances in technology and increasing demand, wearable biosignal monitoring is developing and new applications are emerging. One of the main challenges facing the widespread use of wearable monitoring systems is the motion artifact. The sources of the motion artifact lie in the skin-electrode interface. Reducing the motion and deformation at this interface should have positive e...

متن کامل

INKJET DEPOSITED SILVER NANOPARTICLE ELECTRODES

Silver nanoparticles are being given considerable attention because of their interesting properties and potential applications. One such exploitable use is as the major constituent of conductive inks and pastes used for printing various electronic components. This paper presents a novel direct-writing process for fabrication of the first deposited silver nanoparticles (AgNPs) (50-200nm) elec...

متن کامل

ارزیابی قابلیت افزایش عمر باتری‌های روی‌ـ نقره به‌وسیلۀ بهینه‌سازی فشار پرس به‌کاررفته در تولید الکترودهای نقره

In this study, effect of press pressure used in the production of silver electrodes on the life of zinc - silver oxide batteries was investigated. For this purpose, initially four Ag electrodes (positive plate) with composition of 95 wt% silver oxide, 4.9 wt% carbon powder and 0.1 wt% resin prepared by powder metallurgy method and the press pressures of 40, 60, 80 and 100 bar was applied. Then,...

متن کامل

Operational Cost Analysis for the Treatment of Various Textile Effluents by Electrochemical Process Using Stainless Steel and Aluminum Electrodes

The development of treatment processes from laboratory scale to industries involves a lot of troubles due to the automation of process parameters and fluctuated characteristics of wastewater. In the present study, six different real-time textile effluents of samples such as S1 to S6 are characterized and treated by electrocoagulation process using Stainless Steel (SS) and Aluminum (Al) elec...

متن کامل

The Inkjet Printing of Reducible AgNPs amperometric glucose biosensor Electrodes

The enzymes immobilization of the is crucially effective factor in biosensor preparation. Metal nanoparticles potentially able to immobilize the enzymes according to unique properties including large surface-to-volume ratio, high surface reaction activity, high catalytic efficiency, and strong adsorption ability. A novel and highly sensitive amperometric glucose biosensor was obtained by using ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2013