Evaluation of the use of five laboratory-determined ozone absorption cross sections in Brewer and Dobson retrieval algorithms

نویسندگان

  • A. Redondas
  • R. Evans
چکیده

The primary ground-based instruments used to report total column ozone (TOC) are Brewer and Dobson spectrophotometers in separate networks. These instruments make measurements of the UV irradiances, and through a well-defined process, a TOC value is produced. Inherent to the algorithm is the use of a laboratory-determined crosssection data set. We used five ozone cross-section data sets: three data sets that are based on measurements of Bass and Paur; one derived from Daumont, Brion and Malicet (DBM); and a new set determined by Institute of Experimental Physics (IUP), University of Bremen. The three Bass and Paur (1985) sets are as follows: quadratic temperature coefficients from the IGACO (a glossary is provided in Appendix A) web page (IGQ4), the Brewer network operational calibration set (BOp), and the set used by Bernhard et al. (2005) in the reanalysis of the Dobson absorption coefficient values (B05). The ozone absorption coefficients for Brewer and Dobson instruments are then calculated using the normal Brewer operative method, which is essentially the same as that used for Dobson instruments. Considering the standard TOC algorithm for the Brewer instruments and comparing to the Brewer standard operational calibration data set, using the slit functions for the individual instruments, we find the IUP data set changes the calculated TOC by −0.5 %, the DBM data set changes the calculated TOC by −3.2 %, and the IGQ4 data set at −45 C changes the calculated TOC by +1.3 %. Considering the standard algorithm for the Dobson instruments, and comparing to results using the official 1992 ozone absorption coefficients values and the single set of slit functions defined for all Dobson instruments, the calculated TOC changes by +1 %, with little variation depending on which data set is used. We applied the changes to the European Dobson and Brewer reference instruments during the Izaña 2012 Absolute Calibration Campaign. With the application of a common Langley calibration and the IUP cross section, the differences between Brewer and Dobson data sets vanish, whereas using those of Bass and Paur and DBM produces differences of 1.5 and 2 %, respectively. A study of the temperature dependence of these cross-section data sets is presented using the Arosa, Switzerland, total ozone record of 2003–2006, obtained from two Brewer-type instruments and one Dobsontype instrument, combined with the stratospheric ozone and temperature profiles from the Payerne soundings in the same period. The seasonal dependence of the differences between the results from the various instruments is greatly reduced with the application of temperature-dependent absorption coefficients, with the greatest reduction obtained using the IUP data set.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity of Dobson and Brewer Umkehr ozone profile retrievals to ozone cross-sections and stray light effects

Remote sounding methods are used to derive ozone profile and column information from various groundbased and satellite measurements. Vertical ozone profiles measured in Dobson units (DU) are currently retrieved based on laboratory measurements of the ozone absorption crosssection spectrum between 270 and 400 nm published in 1985 by Bass and Paur (BP). Recently, the US National Aeronautics and S...

متن کامل

Differences between Dobson, Brewer and satellite total ozone

Introduction Conclusions References Tables Figures Back Close Full Screen / Esc Abstract Introduction Conclusions References Tables Figures Back Close Full Screen / Esc Abstract This paper presents key results achieved on analysis of relation between high-quality simultaneous Dobson, Brewer ground and TOMS-V8, GOME-WFDOAS satellite total ozone observations for Hradec Kralove, Czech Republic. St...

متن کامل

Differences between ground Dobson, Brewer and satellite TOMS-8, GOME-WFDOAS total ozone observations at Hradec Kralove, Czech

This paper presents key results achieved by an analysis of the relation between high-quality simultaneous Dobson, Brewer ground and TOMS-V8, GOME-WFDOAS satellite total ozone observations for Hradec Kralove, Czech Republic. Statistically significant seasonal differences with maxima up to 4% of monthly averages have been found between Dobson and Brewer measurements during the winter/spring month...

متن کامل

Reconstruction of Data Gaps in Total-Ozone Records with a New Wavelet Technique

This study introduces a new technique to fill and reconstruct daily observational of Total Ozone records containing void data for some days based on the wavelet theory as a linear time-frequency transformation, which has been considered in various fields of science, especially in the earth and space physics and observational data processing related to the Earth and space sciences. The initial c...

متن کامل

Direct-Sun column ozone retrieval by the ultraviolet multifilter rotating shadow-band radiometer and comparison with those from Brewer and Dobson spectrophotometers.

A methodology for direct-Sun ozone retrieval using the ultraviolet multifilter rotating shadow-band radiometer (UV-MFRSR) is presented. Total vertical column ozone was retrieved in three stations: Mauna Loa, Hawaii, in the U.S., and Regina, Saskatchewan, and Toronto, Ontario, in Canada, from direct solar irradiances of the UV-MFRSR at 325-, 305-, 332-, and 311-nm channels (2-nm FWHM). The total...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014