Nuclear microprobe analysis and imaging: Current state of the art performances
نویسندگان
چکیده
The current state-of-the-art performances claimed for nuclear microbeam spatial resolutions are: (a) 400 nm spot sizes for high current (100 pA) proton beams, (b) 400 nm for high current alpha particle beams, (c) 100 nm for low proton current (co.1 PA) applications such as Scanning Transmission Ion Microscopy (STIM) and Ion Beam Induced Charge (IBIC) and (d) 50 nm for low current alpha particles. These claims, however, have been undermined not only by the lack of a common and generally accepted resolution standard. but also by the lack of a consistent approach between groups regarding a recognised method of beam spot measurement. The lack of a definitive method for assessing spatial resolution is hindering the future development of nuclear microprobes to higher spatial resolutions. We require the manufacture of resolution standards specifically tailored for nuclear microprobe spot size measurements, for both high and low current operations. Until such resolution standards are available, one commercially available standard which has high potential for high current proton beam resolution tests is the Ebeam test chip manufactured for the characterisation of electron beam testers. This chip has patterns as small as 0.5 urn in size produced in 0.5 urn thick aluminium by direct electron beam writing. Using both analytical Particle Induced X-ray Emission (PIXE) imaging and PIXE line scans. the nuclear microscope facility at the National University of Singapore has demonstrated spatial resolutions of less than 400 nm for a 100 pA beam of 2 MeV protons. Low current resolution standards have more stringent requirements. One potential standard tested in Singapore is a prototype self-supporting X-ray mask used in X-ray lithography. This test standard, however, is not commercially available at the moment, is fragile and therefore difficult to handle and easily fractured. Using off-axis STIM imaging and line scanning over this mask. the NUS nuclear microscope facility has demonstrated beam spot sizes less than 130 nm for a 1 pA 2 MeV proton beam.
منابع مشابه
Current state of bone scintigraphy protocols and practice in Japan
Objective(s): Nuclear medicine technologists in Japan often perform additional single-photon emission computed tomography (SPECT) with or without computed tomography (CT) after whole-body imaging for bone scintigraphy. In this study, we wanted to identify the bone scanning protocols used in Japan, together with the current clinical practices. Methods:...
متن کاملComparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction
Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...
متن کاملDetermination of normal ranges of regional and global phase parameters using gated myocardial perfusion imaging with Cedars-Sinai’s QGS software
Introduction: Myocardial perfusion imaging using gated SPECT and phase analysis is an effective tool in evaluation of mechanical dyssynchrony. The purpose of this study was to determine the normal ranges of global and regional phase parameters. Methods: A total of 100 patients with normal resting and stress electrocardiograms, low pretest likelihood for c...
متن کاملThe Status of Stress Myocardial Perfusion Imaging Using 99mTc Pharmaceuticals in Japan: Results from a Nationwide Survey
Objective(s): To appropriately use one-day myocardial perfusion imaging (MPI) with 99mTc radiopharmaceuticals (i.e. to avoid shine-through artifacts), injection doses need to be optimized and dose ratios between the 1st and 2nd scans should be maintained at ≥ 3. However, the current state of practice in Japan is unclear. Thus, the aim of this study was to clarify the details of MPI protocols us...
متن کاملComparison of 6 PET scanners, a simulation study [Persian]
Introduction: Due to the large number of PET systems available in the market, it is not very easy to decide about the scanner of choice. Conducting a research in order to compare all different PET scanners is very time consuming and expensive and practically impossible. However, such comparison may be conducted using PET simulators. In this study, the performance of 6 different PET scanne...