Note: A self-calibrating electrometer for atmospheric charge measurements from a balloon platform.

نویسنده

  • K A Nicoll
چکیده

Charged aerosol particles and water droplets are abundant throughout the lower atmosphere, and may influence interactions between small cloud droplets. This note describes a small, disposable sensor for the measurement of charge in non-thunderstorm cloud, which is an improvement of an earlier sensor [K. A. Nicoll and R. G. Harrison, Rev. Sci. Instrum. 80, 014501 (2009)]. The sensor utilizes a self-calibrating current measurement method. It is designed for use on a free balloon platform alongside a standard meteorological radiosonde, measuring currents from 2 fA to 15 pA and is stable to within 5 fA over a temperature range of 5 °C to -60 °C. During a balloon flight with the charge sensor through a stratocumulus cloud, charge layers up to 40 pC m(-3) were detected on the cloud edges.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A self-calibrating electrometer for atmospheric charge measurements from a balloon platform

Article Accepted Version Nicoll, K. (2013) A self-calibrating electrometer for atmospheric charge measurements from a balloon platform. It is advisable to refer to the publisher's version if you intend to cite from the work. All outputs in CentAUR are protected by Intellectual Property Rights law, including copyright law. Copyright and IPR is retained by the creators or other copyright holders....

متن کامل

Note: A self-calibrating wide range electrometer for in-cloud measurements.

Charge is observed in clouds of all forms, which may influence their development and properties. In-cloud charge measurements require a wide dynamic range, extending from charge in aerosols and dusts to that present in thunderstorms. Unexpectedly large charge densities (>200 pC m-3) have recently been detected in layer clouds using balloon-carried linear electrometers. These, however, lead to i...

متن کامل

Observations of Saharan dust layer electrification

Electrification of atmospheric dust influences the coagulation, wet removal and fall speeds of dust particles. Alignment of dust particles can also occur in fair weather atmospheric electrical conditions if the particles are charged. However, very few electrical measurements made in elevated dust layers exist. Balloon-borne charge and particle instrumentation have been used to investigate the e...

متن کامل

High-resolution Electrometer with Micromechanical Variable Capacitor

We have designed, fabricated, and operated an electrometer with a noise-equivalent resolution of 535 electrons rms (86 aC). The electrometer incorporates a silicon resonator that acts as a variable capacitor and is fabricated using a new self-assembly process that demonstrates for the first time the integration of lownoise, low-leakage JFETs with SOI structures. The resolution of the measuremen...

متن کامل

ELECTROMETER Definition

An electrometer is an electrical instrument for measuring electric charge or electrical potential difference. There are many different types, ranging from historical hand-made mechanical instruments to high-precision electronic devices. Modern electrometers based on vacuum tube or solid state technology can be used to make voltage and charge measurements with very low leakage currents, down to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 84 9  شماره 

صفحات  -

تاریخ انتشار 2013