Recommendation to include methylisothiazolinone in the European baseline patch test series--on behalf of the European Society of Contact Dermatitis and the European Environmental and Contact Dermatitis Research Group.

نویسندگان

  • Magnus Bruze
  • Malin Engfeldt
  • Margarida Gonçalo
  • An Goossens
چکیده

BACKGROUND Methylisothiazolinone (MI) is used as a preservative in occupational and household products, and cosmetics. It is a part of the preparation of methylchloroisothiazolinone (MCI)/MI, which is patch tested in water in the European baseline series. However, this preparation fails to detect a significant percentage of allergic contact reactions to MI. OBJECTIVES To investigate whether a separate test preparation with MI should be included in the European baseline series. METHODS Literature survey. RESULTS In consecutively tested dermatitis patients, the contact allergy rate for MI varies between 0.6% and 6%, with a marked increase in recent years. The contact allergy rate for MI alone, not detected with MCI/MI, varies between 0% and 1.6%. Most cases are relevant, as shown by repeated open application test studies, and are mainly related to exposure from cosmetic products. CONCLUSIONS Owing to the increase in contact allergy to MI not detected with MCI/MI, it is recommended that MI in water at 2000 ppm be included in the European baseline series. With the Finn Chamber(®) (diameter, 8 mm) technique, a volume of 15 µl should be applied, giving a dose of 60 µg/cm(2).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recommendation to increase the test concentration of methylchloroisothiazolinone/methylisothiazolinone in the European baseline patch test series - on behalf of the European Society of Contact Dermatitis and the European Environmental and Contact Dermatitis Research Group.

BACKGROUND Methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI) in aqua is present in the European baseline patch test series at 100 ppm, whereas 200 ppm has been used in Sweden since 1986, in Spain in the late 1980s, and, in recent years, also in the United Kingdom and Ireland. OBJECTIVES With regard to MCI/MI, to investigate the data on contact allergy rates in dermatitis patients, ...

متن کامل

Frequency of contact sensitivity in patients with contact or Atopic Dermatitis with Patch test

Background and aim: Eczema is a common inflammatory skin disease. Although history and physical examination are important in diagnosis of allergen, because of extent of environmental allergens, those are not simply recognized. The objective of this study was to determine allergens in patients with contact or atopic dermatitis referred to Razi hospital.Materials and Meth...

متن کامل

Patch test results in patients with suspected allergic contact dermatitis: a study from Mashhad, Iran and a review of literature

Background: The standard patch test is known as the most reliable test to identify and confirm causative agents of allergic contact dermatitis (ACD). Previous studies have shown that the prevalence of specific allergens varies by geographic area. The results of patch test in patients visiting our dermatology clinics with suspected ACD were prospectively investigated and compared with those repo...

متن کامل

The frequency of skin allergens in patients with contact dermatitis

Background: Eczema is one of the most widely spread inflammatory skin disorders contact dermatitis is an eczematous dermatitis that is produced as a result of contact with a substance in the environment. The substance can act as an irritant or allergen. Every country has allergen particular to itself. Objective: Determining the frequency of skin allergens in patients with contact dermatitis in ...

متن کامل

Frequency of contact sensitization to European Standard Series (ESS) in contact and/or atopic dermatitis patients in Rasht, Ahwaz, Kerman and Hamedan

Background and aim: The frequency of sensitization to contact allergens varies in different countries because of both genetic and, more importantly, allergen exposure variations. The objective is to determine the frequency of sensitization to contact allergens in Iranian patients with dermatitis.Materials and methods: Four hundreds and one patients with a clinical diagn...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Contact dermatitis

دوره 69 5  شماره 

صفحات  -

تاریخ انتشار 2013