Retention of platelets by glass bead filters.

نویسندگان

  • W R Pitney
  • M Potter
چکیده

Whole blood was passed through glass bead filters and the retention of platelets studied under various experimental conditions. Platelet retention was similar over a wide range of blood flow rates; however, it was decreased at fast rates of flow. Platelet retention was not influenced by the haematocrit value of the blood over a wide range. Retention in filters containing siliconized beads was similar to that in filters with untreated beads. Platelet retention was inhibited by the addition of citrate or adenosine to the blood before passage through the filter and was also less when the blood was cooled. Heparin and phenylindandione therapy did not affect the results. There was a wide range of results of platelet retention tests with normal blood samples and considerable variability between the results of duplicate samples from the same donor. Repeated testing of normal donors over a three-month period gave results which varied widely within the normal range. Twenty-two of 40 uraemic blood samples showed decreased platelet retention. The mechanism of platelet retention from whole blood by glass bead filters is not clear but may be related to platelet aggregation induced by adenosine diphosphate or other aggregating agents.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship of platelet retention in glass bead columns to the rate of aggregation with adenosine diphosphate and thrombin.

The initial rate of platelet aggregation induced by adenosine diphosphate and thrombin correlated with the number of platelets retained when samples of citrated blood from the same normal donors were passed through glass bead columns. The results support the view that the glass bead column method of measuring platelet ;adhesiveness' is influenced by platelet aggregation.

متن کامل

Comparison of platelet glass bead retention techniques in patients with clinical bleeding disorders.

Platelet glass bead retention by the Salzman and infusion pump techniques were compared in 36 control individuals, 10 patients with von Willebrand's syndrome and four patients with thrombocytopathies. No significant differences between the results of the two assays were observed. Eleven percent or less of the control individuals had diminished platelet glass bead retention. The mean percentage ...

متن کامل

Platelet retention in glass bead columns: adhesion to glass and subsequent platelet-platelet interactions.

In normal heparinized blood, the retention of platelets in glass bead columns was low in the first 1 or 2 ml, increasing to more than 80% by the 4th or 5th ml. Prior flushing of the columns with platelet-poor plasma or saline lowered retention in all 5 ml. Additional studies were carried out with a two-stage procedure in which a sample of blood (A) was pumped through a column, immediately flush...

متن کامل

Factors Affecting the Adhesiveness of Human Leucocytes and Platelets in Vitro

Some factors affecting the retention of human polymorphonuclear neutrophils (PMN), lymphocytes, and platelets on a siliconized glass bead column were explored. PMN were more effectively retained when the flow rates were slow and the columns long. They were found largely on the upper portions of the columns except with rapid flow rates when they spread down the columns. PMN retention on the colu...

متن کامل

Platelet retention in glass bead columns: further evidence for the importance of ADP.

Plasma of normal heparinized blood contained 0.284 pM ± SD 0.097 (ADP + ATP) with an ATP:ADP ratio of 2.5:1. Plasma from thrombocytopenic blood contained only 0.106 pM ± 0.073 (ADP + ATP). Blood with normal platelet retention released 0.234 pM ± 0.187 (ADP + ATP) during passage through a glass bead column, with an ATP:ADP ratio of 1.6:1. Significantly less was released in blood with low retenti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 20 5  شماره 

صفحات  -

تاریخ انتشار 1967