Anterior mitral leaflet curvature in the beating ovine heart: a case study using videofluoroscopic markers and subdivision surfaces.

نویسندگان

  • S Göktepe
  • W Bothe
  • J-P E Kvitting
  • J C Swanson
  • N B Ingels
  • D C Miller
  • Ellen Kuhl
چکیده

The implantation of annuloplasty rings is a common surgical treatment targeted to re-establish mitral valve competence in patients with mitral regurgitation. It is hypothesized that annuloplasty ring implantation influences leaflet curvature, which in turn may considerably impair repair durability. This research is driven by the vision to design repair devices that optimize leaflet curvature to reduce valvular stress. In pursuit of this goal, the objective of this manuscript is to quantify leaflet curvature in ovine models with and without annuloplasty ring using in vivo animal data from videofluoroscopic marker analysis. We represent the surface of the anterior mitral leaflet based on 23 radiopaque markers using subdivision surfaces techniques. Quartic box-spline functions are applied to determine leaflet curvature on overlapping subdivision patches. We illustrate the virtual reconstruction of the leaflet surface for both interpolating and approximating algorithms. Different scalar-valued metrics are introduced to quantify leaflet curvature in the beating heart using the approximating subdivision scheme. To explore the impact of annuloplasty ring implantation, we analyze ring-induced curvature changes at characteristic instances throughout the cardiac cycle. The presented results demonstrate that the fully automated subdivision surface procedure can successfully reconstruct a smooth representation of the anterior mitral valve from a limited number of markers at a high temporal resolution of approximately 60 frames per minute.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Regional stiffening of the mitral valve anterior leaflet in the beating ovine heart.

Left atrial muscle extends into the proximal third of the mitral valve (MV) anterior leaflet and transient tensing of this muscle has been proposed as a mechanism aiding valve closure. If such tensing occurs, regional stiffness in the proximal anterior mitral leaflet will be greater during isovolumic contraction (IVC) than isovolumic relaxation (IVR) and this regional stiffness difference will ...

متن کامل

Stress-strain behavior of mitral valve leaflets in the beating ovine heart.

Excised anterior mitral leaflets exhibit anisotropic, non-linear material behavior with pre-transitional stiffness ranging from 0.06 to 0.09 N/mm(2) and post-transitional stiffness from 2 to 9 N/mm(2). We used inverse finite element (FE) analysis to test, for the first time, whether the anterior mitral leaflet (AML), in vivo, exhibits similar non-linear behavior during isovolumic relaxation (IV...

متن کامل

Material properties of the ovine mitral valve anterior leaflet in vivo from inverse finite element analysis.

We measured leaflet displacements and used inverse finite-element analysis to define, for the first time, the material properties of mitral valve (MV) leaflets in vivo. Sixteen miniature radiopaque markers were sewn to the MV annulus, 16 to the anterior MV leaflet, and 1 on each papillary muscle tip in 17 sheep. Four-dimensional coordinates were obtained from biplane videofluoroscopic marker im...

متن کامل

Anterior mitral leaflet curvature during the cardiac cycle in the normal ovine heart.

BACKGROUND The dynamic changes of anterior mitral leaflet (AML) curvature are of primary importance for optimal left ventricular filling and emptying but are incompletely characterized. METHODS AND RESULTS Sixteen radiopaque markers were sutured to the AML in 11 sheep, and 4-dimensional marker coordinates were acquired with biplane videofluoroscopy. A surface subdivision algorithm was applied...

متن کامل

Rigid, complete annuloplasty rings increase anterior mitral leaflet strains in the normal beating ovine heart.

BACKGROUND Annuloplasty ring or band implantation during surgical mitral valve repair perturbs mitral annular dimensions, dynamics, and shape, which have been associated with changes in anterior mitral leaflet (AML) strain patterns and suboptimal long-term repair durability. We hypothesized that rigid rings with nonphysiological three-dimensional shapes, but not saddle-shaped rigid rings or fle...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biomechanics and modeling in mechanobiology

دوره 9 3  شماره 

صفحات  -

تاریخ انتشار 2010