Diagnostic performance of visual field test using subsets of the 24-2 test pattern for early glaucomatous field loss.

نویسندگان

  • Yanfang Wang
  • David B Henson
چکیده

PURPOSE To explore the diagnostic performance of threshold visual field tests using subsets of the standard 24-2 test pattern in detecting early/moderate glaucomatous field loss. METHODS Normal (Brusini stage 0, n = 2344) and defective eyes (Brusini stage 2-3, n = 2222) from a database of visual field tests (6696 eyes/3586 patients, SITA standard 24-2 algorithm) were selected and resampled using a bootstrap method. The positive predictive values (PPVs) of each test location were calculated for the resampled datasets with a fail criteria of a single missed stimulus at a pattern deviation probability level of less than 0.01. Optimized test patterns started with the most frequent location of the maximum PPV in datasets. Eyes missing the location were removed and the PPV values of residual sample recalculated. The process was repeated until all defective eyes were detected. Receiver operating characteristic (ROC) curves were established for the PPV-optimized and five randomized patterns. Characteristics of visual field defects detected with subsets of optimized test pattern were established. RESULTS With the PPV-optimized pattern, 95% of the field defects were detected with 30 locations and all with 43 locations. Areas under the ROC curve were greatest for the optimized pattern. With each increment in the number of test locations, the Mean Deviation of additionally detected eyes became more positive while Pattern Standard Deviation became less positive (P < 0.001). CONCLUSIONS Good diagnostic performance can be obtained with optimized subsets of the standard 24-2 test pattern that can provide substantial savings in test times.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the effects of glaucomatous (POAG) damage on the mVEP parameters

Introduction: Glaucoma is considered as a major cause of irreversible vision loss, worldwide. Glaucoma includes a diverse ophthalmopathies characterized by attenuating the neural and connective tissue segments and eventually progression of specific patterns of visual dysfunction. Currently, perimetry is known as the most accurate diagnostic method in glaucoma and its follow up...

متن کامل

Frequency doubling technology perimetry for detection of glaucomatous visual field loss.

PURPOSE To evaluate the ability of frequency doubling technology perimetry to detect early, moderate, and advanced glaucomatous visual field loss. METHODS In a prospective study, frequency doubling technology perimetry (C-20 full threshold) was performed in the right eye of 254 normal control subjects and 230 patients with early (n = 85), moderate (n = 114), or advanced (n = 31) glaucomatous ...

متن کامل

Evaluation of Hemifield Sector Analysis Protocol in Multifocal Visual Evoked Potential Objective Perimetry for the Diagnosis and Early Detection of Glaucomatous Field Defects

PURPOSE Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, an...

متن کامل

The role of hemifield sector analysis in multifocal visual evoked potential objective perimetry in the early detection of glaucomatous visual field defects

OBJECTIVE The purpose of this study was to examine the effectiveness of a new analysis method of mfVEP objective perimetry in the early detection of glaucomatous visual field defects compared to the gold standard technique. METHODS AND PATIENTS Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes), and glaucoma suspect patients (38 eyes). All subjects ...

متن کامل

Detecting visual function abnormalities using the Swedish interactive threshold algorithm and matrix perimetry in eyes with glaucomatous appearance of the optic disc.

OBJECTIVE To compare the ability of 24-2 frequency-doubling perimetry (FDP-Matrix) with standard automated perimetry with the Swedish interactive threshold algorithm (SAP-SITA) in detection of visual function abnormalities in patients with glaucomatous-appearing optic discs (GAOD). METHODS This observational case-control study included 80 patients with GAOD and 54 control subjects diagnosed b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 54 1  شماره 

صفحات  -

تاریخ انتشار 2013