A randomized prospective controlled trial comparing the laryngeal tube suction disposable and the supreme laryngeal mask airway: the influence of head and neck position on oropharyngeal seal pressure

نویسندگان

  • Mostafa Somri
  • Sonia Vaida
  • Gustavo Garcia Fornari
  • Gabriela Renee Mendoza
  • Pedro Charco-Mora
  • Naser Hawash
  • Ibrahim Matter
  • Forat Swaid
  • Luis Gaitini
چکیده

BACKGROUND The Laryngeal Tube Suction Disposable (LTS-D) and the Supreme Laryngeal Mask Airway (SLMA) are second generation supraglottic airway devices (SADs) with an added channel to allow gastric drainage. We studied the efficacy of these devices when using pressure controlled mechanical ventilation during general anesthesia for short and medium duration surgical procedures and compared the oropharyngeal seal pressure in different head and-neck positions. METHODS Eighty patients in each group had either LTS-D or SLMA for airway management. The patients were recruited in two different institutions. Primary outcome variables were the oropharyngeal seal pressures in neutral, flexion, extension, right and left head-neck position. Secondary outcome variables were time to achieve an effective airway, ease of insertion, number of attempts, maneuvers necessary during insertion, ventilatory parameters, success of gastric tube insertion and incidence of complications. RESULTS The oropharyngeal seal pressure achieved with the LTS-D was higher than the SLMA in, (extension (p=0.0150) and right position (p=0.0268 at 60 cm H2O intracuff pressures and nearly significant in neutral position (p = 0.0571). The oropharyngeal seal pressure was significantly higher with the LTS-D during neck extension as compared to SLMA (p= 0.015). Similar oropharyngeal seal pressures were detected in all other positions with each device. The secondary outcomes were comparable between both groups. Patients ventilated with LTS-D had higher incidence of sore throat (p = 0.527). No major complications occurred. CONCLUSIONS Better oropharyngeal seal pressure was achieved with the LTS-D in head-neck right and extension positions , although it did not appear to have significance in alteration of management using pressure control mechanical ventilation in neutral position. The fiberoptic view was better with the SLMA. The post-operative sore throat incidence was higher in the LTS-D. TRIAL REGISTRATION ClinicalTrials.gov ID: NCT02856672 , Unique Protocol ID:BnaiZionMC-16-LG-001, Registered: August 2016.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erratum to: A randomized prospective controlled trial comparing the laryngeal tube suction disposable and the supreme laryngeal mask airway: the influence of head and neck position on oropharyngeal seal pressure

Erratum In the version of this article that was published on PubMed Central [1] the author’s name “Gustavo Garcia Fornari” was formatted incorrectly in the XML mark up and appeared incorrectly on PubMed Central. In the Mark up, “Gustavo Garcia” was added as the Given Name and “Fornari” was the Family Name, but the Family Name should have been “Garcia Fornari” and the Given Name “Gustavo”. Due t...

متن کامل

Comparison of Five 2nd-Generation Supraglottic Airway Devices for Airway Management Performed by Novice Military Operators

OBJECTIVES Five different second-generation supraglottic airway devices, ProSeal LMA, Supreme LMA, i-gel, SLIPA, and Laryngeal Tube Suction-D, were studied. Operators were inexperienced users with a military background, combat lifesavers, nurses, and physicians. METHODS This was a prospective, randomized, single-blinded study. Devices were inserted in the operating room in low light condition...

متن کامل

Limitation of Laryngeal Mask Airway Usage in Open-Neck Procedure

I read the manuscript entitled “Case Report of An Open Neck Procedure Complication Associated with Laryngeal Mask Airway Use” by Subramaniam T et al. This is a valuable manuscript describing iatrogenic complications during level-2 cervical lymph node biopsy, in which the airway is managed with laryngeal mask airway (LMA). During the procedure, the surgeon realized that the mass was actually the...

متن کامل

Comparing the Effect of Laryngeal Mask Airway And Endotracheal Tube Insertion on Intraocular Pressure in Cataract Surgery

Background and purpose: The method of anesthesia affects intraocular pressure (IOP), especially general anesthesia which is sometimes administered with endotracheal tube (ETT) insertion. The aim of this research was to compare the effect of laryngeal mask airway (LMA) and ETT on intraocular pressure in cataract surgery. Materials and methods: In a single blind randomized clinical trial, 61 pat...

متن کامل

Comparison of the Incidence of Sore Throat and Hemodynamic Changes in ‎Airway Management by Macintosh, Glideoscope Laryngoscope and ‎Laryngeal Mask Airway Techniques: Randomized Controlled Trial

Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway  techniques in elective surg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015