The purpose of this study was to compare dosimetric parameters of treatment plans among four techniques for preoperative single-fraction partial breast radiotherapy in order to select an optimal treatment technique. The techniques evaluated were noncoplanar 3D conformal radiation therapy (3D CRT), noncoplanar intensity-modulated radiation therapy (IMRTNC), coplanar IMRT (IMRTCO), and volumetric-modulated arc therapy (VMAT). The planning CT scans of 16 patients in the prone position were used in this study, with the single-fraction prescription doses of 15 Gy for the first eight patients and 18 Gy for the remaining eight patients. Six (6) MV photon beams were designed to avoid the heart and contralateral breast. Optimization for IMRT and VMAT was performed to reduce the dose to the skin and normal breast. All plans were normalized such that 100% of the prescribed dose covered greater than 95% of the clinical target volume (CTV) consisting of gross tumor volume (GTV) plus 1.5 cm margin. Mean homogeneity index (HI) was the lowest (1.05 ± 0.02) for 3D CRT and the highest (1.11 ± 0.04) for VMAT. Mean conformity index (CI) was the lowest (1.42 ± 0.32) for IMRTNC and the highest (1.60 ± 0.32) for VMAT. Mean of the maximum point dose to skin was the lowest (73.7 ± 11.5%) for IMRTNC and the highest (86.5 ± 6.68%) for 3D CRT. IMRTCO showed very similar HI, CI, and maximum skin dose to IMRTNC (differences <1%). The estimated mean treatment delivery time, excluding the time spent for patient positioning and imaging, was 7.0 ± 1.0, 8.3 ± 1.1, 9.7 ± 1.0, and 11.0 ± 1.5min for VMAT, IMRTCO, IMRTNC and 3D CRT, respectively. In comparison of all four techniques for preoperative single-fraction partial breast radiotherapy, we can conclude that noncoplanar or coplanar IMRT were optimal in this study as IMRT plans provided homogeneous and conformal target coverage, skin sparing, and relatively short treatment delivery time.
منابع مشابه
Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions
Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...
متن کاملCoplanar versus noncoplanar intensity‐modulated radiation therapy (IMRT) and volumetric‐modulated arc therapy (VMAT) treatment planning for fronto‐temporal high‐grade glioma†
The purpose of this study was to compare dosimetric and radiobiological parameters of treatment plans using coplanar and noncoplanar beam arrangements in patients with fronto-temporal high-grade glioma (HGG) generated for intensity-modulated radiotherapy (IMRT) or volumetric-modulated arc therapy (VMAT). Ten cases of HGG overlapping the optic apparatus were selected. Four separate plans were cr...
متن کاملDosimetric Comparison of Volumetric Modulated Arc Therapy (VMAT), 5F Intensity Modulated Radiotherapy (IMRT) and 3D Conformal Radiotherapy (3DCRT) in Rectal Carcinoma Receiving Neoadjuvant Chemoradiotherapy
Objective: To investigate better dosimetric distribution of volumetric modulated arc therapy (VMAT) vs. 5F intensity modulated radiotherapy (IMRT) and 3D conformal radiotherapy (3DCRT) in patients with locally advanced rectal cancer (LARC) when treated with neoadjuvant chemoradiotherapy. Methods: 3D-CRT, 5F-IMRT and VMAT plans for preoperative radiotherapy were designed in 12 patients with loca...
متن کاملA dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer
BACKGROUND To compare 3 Dimensional Conformal radiotherapy (3D-CRT) with Intensity Modulated Radiotherapy (IMRT) with Volumetric-Modulated Arc Therapy (VMAT) for bladder cancer. METHODS Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planni...
متن کاملVolumetric-modulated arc radiotherapy for pancreatic malignancies: dosimetric comparison with sliding-window intensity-modulated radiotherapy and 3-dimensional conformal radiotherapy.
Volumetric-modulated arc radiotherapy (VMAT) is an iteration of intensity-modulated radiotherapy (IMRT), both of which deliver highly conformal dose distributions. Studies have shown the superiority of VMAT and IMRT in comparison with 3-dimensional conformal radiotherapy (3D-CRT) in planning target volume (PTV) coverage and organs-at-risk (OARs) sparing. This is the first study examining the be...