Radiometric detection of bacteremia: requirement for terminal subcultures.

نویسندگان

  • R R Strauss
  • R Throm
  • H Friedman
چکیده

A radiometric procedure for rapid detection of bacteria in clinical blood specimens was utilized over a period of 1 year in this laboratory. Although in initial studies it was felt that all positive bacteremias would be detected by radiometric examination of cultures for 14CO2 evolution over a 7-day period, we found in the present study that a significant number of bacteria were not detected, except by blind subculturing on day 7 before discarding the culture sample. Microorganisms were detected in 490 individual specimens from 348 patients after examination of 6,200 individual blood specimens, both anaerobically and aerobically. All but 30 of the positive specimens were detected by the radiometric procedure, with an average detection time of 30.5 h. Thirty organisms, representing 6% of the total organisms isolated, were not detected by the BACTEC apparatus. The predominating organisms missed by the radiometric method were group D streptococci, both enterococcal and non-enterococcal species. These isolates represented two-thirds of the total number of organisms not detected by the radiometric procedure. A majority of bacteria detected only upon terminal subculture were isolates from a very small number of patients, suggesting that these organisms might have specific properties that preclude their detection by radiometric assay. Nevertheless, our study results indicate that it is essential that all radiometrically examined blood culture specimens be subcultured prior to discard in order to lessen the likelihood of missing a microbial pathogen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Controlled evaluation of supplemented peptone and Bactec blood culture broths for the detection of bacteremia and fungemia.

Comparison of conventional blood culture media with newer formulations of Bactec media for radiometric detection are lacking. Therefore, we compared the yield and speed of detection of clinically important microorganisms with supplemented peptone broth (SPB) and Bactec aerobic (6B) and anaerobic (7C or 7D) broths in 7,627 blood samples from adult patients. Acridine orange stains from SPB, radio...

متن کامل

Effect of agitation and terminal subcultures on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system.

In an initial evaluation, we found the Oxoid Signal blood culture system inferior to the BACTEC radiometric system for detection of some microorganisms causing septicemia (M. P. Weinstein, S. Mirrett, and L. B. Reller, J. Clin. Microbiol. 26:962-964, 1988). To determine whether modified processing of the Oxoid Signal blood culture system could improve its yield and speed of detecting positive c...

متن کامل

Lack of requirement for blind subcultures of BACTEC blood culture media.

To determine the need for blind subculturing of BACTEC (Johnston Laboratories, Cockeysville, Md.) blood culture media, we compared results of radiometric readings, visual inspection, and blind subculturing for nearly 7,500 blood specimens. Visual inspection and radiometric testing were performed on day 1 through 7, and blind subcultures were made on day 3. In the first phase of the study, 402 o...

متن کامل

Radiometric detection of bacteremia in neonates.

The predicted prevalence of false positive blood cultures due to hyperactive neonatal blood cells in a radiometric detection system was confirmed. Suppression of this blood background radioactivity in the system was achieved by using a hypertonic medium containing 10% sucrose. The radiometric system produced accurate results as fast as the conventional blood culturing method, saved labor and mi...

متن کامل

Radiometric method for detection of bacteremia.

A study was performed with simulated blood cultures to evaluate the production of (14)CO(2) as an index of bacterial growth. With a range of inoculum sizes from 4 to 4,250 colony-forming units, it was not possible to detect (14)CO(2) within 6 hr after inoculation in 59 separate experiments. In a limited trial with patients' blood cultures, the radiometric method failed to provide any earlier ev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 5 2  شماره 

صفحات  -

تاریخ انتشار 1977