Coiled-tube heat exchanger for High-Pressure Metal Hydride hydrogen storage systems – Part 1. Experimental study

نویسندگان

  • Milan Visaria
  • Issam Mudawar
چکیده

This two-part study explores the development and thermal performance of a coiled-tube heat exchanger for hydrogen fuel cell storage systems utilizing High-Pressure Metal Hydride (HPMH). The primary purpose of this heat exchanger is to tackle the large amounts of heat released from the exothermic hydriding reaction that occurs when the hydrogen is charged into the storage vessel and is absorbed by the HPMH. The performance of heat exchanger was tested using 4 kg of Ti1.1CrMn at pressures up to 280 bar. Tests were performed to assess the influence of different operating conditions on the effectiveness of the heat exchanger at removing the heat in a practical fill time (time required to complete 90% of the hydriding reaction). It is shown that distance of metal hydride particles from the coolant tube has the most dominant influence on hydriding rate, with particles closer to the tube completing their hydriding reaction sooner. Faster fill times were achieved by reducing coolant temperature and to a lesser extent by increasing pressurization rate. By comparing tests with and without coolant flow, it is shown that the heat exchanger reduces fill time by 75% while occupying only 7% of the storage pressure vessel volume. The second part of this study will present a 3D computational heat transfer model of the storage vessel and heat exchanger, and compare the model predictions to the experimental data. 2011 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coiled-tube heat exchanger for high-pressure metal hydride hydrogen storage systems – Part 2. Computational model

This second part of a two-part study presents a transient, three-dimensional numerical model for a highpressure metal hydride (HPMH) hydrogen storage system that is cooled by a coiled-tube heat exchanger. The model uses the same geometry examined in the first part of the study and its predictions are compared to experimental results also discussed in the first part. The model involves solving c...

متن کامل

Experimental investigation and theoretical modeling of dehydriding process in high-pressure metal hydride hydrogen storage systems

This study explores the endothermic dehydriding (desorption) reaction that takes place in a high-pressure metal hydride (HPMH) hydrogen storage system when hydrogen gas is released to the fuel cell. The reaction is sustained by circulating warm fluid through a heat exchanger embedded in the HPMH powder. A systematic approach to modeling the dehydriding process is presented, which is validated a...

متن کامل

Enhanced heat exchanger design for hydrogen storage using high-pressure metal hydride – Part 2. Experimental results

0017-9310/$ see front matter 2010 Elsevier Ltd. A doi:10.1016/j.ijheatmasstransfer.2010.09.028 ⇑ Corresponding author. Tel.: +1 (765) 494 5705; fa E-mail address: [email protected] (I. Mud Hydrogen storage systems utilizing high-pressure metal hydrides (HPMHs) require a highly effective heat exchanger to remove the large amounts of heat released once the hydrogen is charged into the system...

متن کامل

Transient thermal study of recuperative tube in tube heat exchanger operating in refrigeration system using experimental test and mathematical simulation

Joule-Thomson cooling systems are used in refrigeration and liquefaction processes. There are extensive studies on Joule-Thomson cryogenic systems, but most of them coverage steady state conditions or lack from experimental data. In the present work, transient thermal behavior of Joule-Thomson cooling system including counter current helically coiled tube in tube heat exchanger, expansion valve...

متن کامل

How to Design a Cryogenic Joule-Thomson Cooling System: Case Study of Small Hydrogen Liquefier

Heat exchangers are the critical components of refrigeration and liquefaction processes. Selection of appropriate operational conditions for cryogenic recuperative heat exchanger and expansion valve operating in Joule-Thomson cooling system results in improving the performance and efficiency. In the current study, a straightforward procedure is introduced to design an efficient Joule-Thomson co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011