Time-Efficient Black Blood RCA Wall Imaging at 3T Using Improved Motion Sensitized Driven Equilibrium (iMSDE): Feasibility and Reproducibility

نویسندگان

  • Jinnan Wang
  • Suzanne C. Gerretsen
  • Jeffrey H. Maki
  • Caroline Jaarsma
  • M. Eline Kooi
  • Daniel Herzka
  • Baocheng Chu
  • Vasily L.Yarnykh
  • Chun Yuan
  • Tim Leiner
چکیده

BACKGROUND The aim of this study was to explore the feasibility and reproducibility of a time-efficient coronary vessel wall measurement approach using an improved motion-sensitized driven equilibrium (iMSDE) pulse sequence. METHODOLOGY In this study, the iMSDE pulse sequence was first optimized and then applied on a group of healthy volunteers (N = 10) to evaluate its feasibility of vessel wall visualization. The same technique was also applied on a separate group of volunteers (N = 19) for a reproducibility study by scanning the same subject in two separate sessions. The iMSDE sequence was found to provide good coronary vessel wall delineation. It was also found to provide reproducible coronary vessel wall diameter and thickness measurements in both proximal and middle segments of the right coronary artery. CONCLUSION The feasibility and reproducibility of iMSDE based coronary vessel wall imaging were demonstrated for the first time, paving the way for further testing in a clinical environment for fast and accurate coronary artery disease detection.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of improved motion-sensitized driven equilibrium (iMSDE) for multi-contrast vessel wall screening.

PURPOSE We assessed the improved motion-sensitized driven equilibrium (iMSDE) technique for multiple contrast 3-dimensional vessel wall imaging at 3T. METHODS Carotid images were obtained using iMSDE combined with turbo field echo (iMSDE-TFE) and conventional double inversion-recovery turbo spin-echo (DIR-TSE) in 5 healthy adult subjects. The tissue signal-to-noise efficiency (SNReff), SNR di...

متن کامل

Optimization of Improved Motion-sensitized Driven-equilibrium (iMSDE) blood suppression for carotid artery wall imaging

BACKGROUND Improved motion-sensitized driven-equilibrium (iMSDE) preparations have been successfully used in carotid artery wall imaging to achieve blood suppression, but it causes notable signal loss, mostly due to inherent T2 decay, eddy current effects and B1 + inhomogeneity. In this study, we investigate the signal to noise ratio (SNR) and blood suppression performance of iMSDE using compos...

متن کامل

Sub-minute 3D black-blood imaging of the whole heart with isotropic spatial resolution

Introduction Evaluation of cardiac morphology is an important part of routine diagnostic applications of cardiac MRI in various pathological conditions, such as congenital abnormalities, myocardial infarction, cardiomyopathies, and tumors. A previous technical approach for morphological cardiac MRI is based on a 2D black-blood fast spin-echo sequence with double inversion-recovery (DIR) blood s...

متن کامل

[Optimization of black blood CINE for mobile plaque].

For examining carotid plaque, black blood (BB) magnetic resonance (MR) imaging can diagnose plaque components based on MR signals. Dynamic images for evaluating the mobility of carotid plaque may also be useful as an adjunct to the diagnosis of carotid plaque. The aim of this study was to find optimal parameters for dynamic images using the black blood technique (BB CINE). All experiments were ...

متن کامل

Efficacy of Maximum Intensity Projection of Contrast-Enhanced 3D Turbo-Spin Echo Imaging with Improved Motion-Sensitized Driven-Equilibrium Preparation in the Detection of Brain Metastases

OBJECTIVE To evaluate the diagnostic benefits of 5-mm maximum intensity projection of improved motion-sensitized driven-equilibrium prepared contrast-enhanced 3D T1-weighted turbo-spin echo imaging (MIP iMSDE-TSE) in the detection of brain metastases. The imaging technique was compared with 1-mm images of iMSDE-TSE (non-MIP iMSDE-TSE), 1-mm contrast-enhanced 3D T1-weighted gradient-echo imaging...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011