A New 3D Tool for Assessing the Accuracy of Bimaxillary Surgery: The OrthoGnathicAnalyser.

نویسندگان

  • Frank Baan
  • Jeroen Liebregts
  • Tong Xi
  • Ruud Schreurs
  • Martien de Koning
  • Stefaan Bergé
  • Thomas Maal
چکیده

AIM The purpose of this study was to present and validate an innovative semi-automatic approach to quantify the accuracy of the surgical outcome in relation to 3D virtual orthognathic planning among patients who underwent bimaxillary surgery. MATERIAL AND METHOD For the validation of this new semi-automatic approach, CBCT scans of ten patients who underwent bimaxillary surgery were acquired pre-operatively. Individualized 3D virtual operation plans were made for all patients prior to surgery. During surgery, the maxillary and mandibular segments were positioned as planned by using 3D milled interocclusal wafers. Consequently, post-operative CBCT scan were acquired. The 3D rendered pre- and postoperative virtual head models were aligned by voxel-based registration upon the anterior cranial base. To calculate the discrepancies between the 3D planning and the actual surgical outcome, the 3D planned maxillary and mandibular segments were segmented and superimposed upon the postoperative maxillary and mandibular segments. The translation matrices obtained from this registration process were translated into translational and rotational discrepancies between the 3D planning and the surgical outcome, by using the newly developed tool, the OrthoGnathicAnalyser. To evaluate the reproducibility of this method, the process was performed by two independent observers multiple times. RESULTS Low intra-observer and inter-observer variations in measurement error (mean error < 0.25 mm) and high intraclass correlation coefficients (> 0.97) were found, supportive of the observer independent character of the OrthoGnathicAnalyser. The pitch of the maxilla and mandible showed the highest discrepancy between the 3D planning and the postoperative results, 2.72° and 2.75° respectively. CONCLUSION This novel method provides a reproducible tool for the evaluation of bimaxillary surgery, making it possible to compare larger patient groups in an objective and time-efficient manner in order to optimize the current workflow in orthognathic surgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Procedural Modeling as an Analytical Tool for 3D Survey in Urban Design Assessment

This paper examines procedural modeling as a tool for 3D modeling creation. Procedural modeling historically has been used for 3D visualization of natural features, but with the release of the software CityEngine in 2008, the technology can easily be adopted also in problem domains dealing with urban environments. Then, we will examine and compare two types of modeling, traditional and proc...

متن کامل

Value of Prophylactic Postoperative Antibiotic Therapy after Bimaxillary Orthognathic Surgery: A Clinical Trial

Introduction: Antibiotic therapy before or after orthognathic surgery is commonly recommended by surgeons to minimize the risk of wound infection. This article evaluates the value of Prophylactic antibiotic therapy in order to diminish the incidence of postoperative wound infection after orthognathic surgery.   Materials and Methods: Fifty candidates for bimaxillary orthognathic surgery were di...

متن کامل

I-44: 3D Ultrasonography of Ovarian Tumors

A prospective study was conducted at the OB/GYN department of Kasr El Eini hospital, Cairo University from Jan 2000 - Oct 2002. The study included 51 patients in the age group between 40-70 years (including pre and post menopausal women). All patients were subjected to following after taking a consent from each patient: Complete clinical evaluation; including history taking and clinical examina...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

Changes of the Posterior Airway Space Following Orthognathic Surgery in Class III

Objective: Adaptation of the pharyngeal airway space does occur after different surgical strategies of class III patients including mandibular setback, maxillary advancement and bimaxillary surgery. The aim of this study is to conduct a detailed cephalometric evaluation of the alterations taking place in the morphology of the pharyngeal airway space after treatment of class III skeletal deformi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • PloS one

دوره 11 2  شماره 

صفحات  -

تاریخ انتشار 2016