Long-term Mortality Predictors in Patients with Small Aortic Annulus Undergoing Aortic Valve Replacement with a 19- or 21-mm Bioprosthesis

نویسندگان

  • Jenny Lourdes Rivas de Oliveira
  • Renato Tambellini Arnoni
  • Magaly Arrais dos Santos
  • Antonio Flávio Sanchez Almeida
  • Mário Issa
  • Antoninho Sanfins Arnoni
  • Paulo Chaccur
  • Luiz Carlos Bento de Souza
چکیده

Introduction Replacement of the aortic valve in patients with a small aortic annulus is associated with increased morbidity and mortality. A prosthesis-patient mismatch is one of the main problems associated with failed valves in this patient population. Objective To evaluate the long-term mortality predictors in patients with a small aortic annulus undergoing aortic valve replacement with a bioprosthesis. Methods In this retrospective observational study, a total of 101 patients undergoing aortic valve replacement from January 2000 to December 2010 were studied. There were 81 (80.19%) women with a mean age of 52.81±18.4 years. Severe aortic stenosis was the main indication for surgery in 54 (53.4%) patients. Posterior annulus enlargement was performed in 16 (15.8%) patients. Overall, 54 (53.41%) patients underwent concomitant surgery: 28 (27.5%) underwent mitral valve replacement, and 13 (12.7%) underwent coronary artery bypass graft surgery. Results Mean valve index was 0.82±0.08 cm(2)/m(2). Overall, 17 (16.83%) patients had a valve index lower than 0.75 cm(2)/m(2), without statistical significance for mortality (P=0.12). The overall 10-year survival rate was 83.17%. The rate for patients who underwent isolated aortic valve replacement was 91.3% and 73.1% (P=0.02) for patients who underwent concomitant surgery. In the univariate analysis, the main predictors of mortality were preoperative ejection fraction (P=0.02; HR 0.01) and EuroSCORE II results (P=0.00000042; HR 1.13). In the multivariate analysis, the main predictors of mortality were age (P=0.01, HR 1.04) and concomitant surgery (P=0.01, HR 5.04). Those relationships were statistically significant. Conclusion A valve index of < 0.75 cm(2)/m(2) did not affect 10-year survival. However, concomitant surgery and age significantly affected mortality.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

Transcatheter aortic valve implantation in patients with severe aortic stenosis and small aortic annulus.

OBJECTIVES Valve hemodynamics and clinical outcomes among patients with a small aortic annulus who underwent transcatheter aortic valve implantation (TAVI) were examined. BACKGROUND The presence of a small aortic annulus may complicate the surgical management of patients with severe aortic stenosis (AS). TAVI is an alternative to aortic valve replacement (AVR) in high-risk patients, but few d...

متن کامل

Long-term clinical outcomes 15 years after aortic valve replacement with the Freestyle stentless aortic bioprosthesis.

BACKGROUND The Freestyle stentless aortic root bioprosthesis has excellent hemodynamics and durability through 10 years. The purpose of this report is to present clinical outcomes in a large multicenter cohort through 15 years. METHODS The multicenter evaluation of the Freestyle valve began in 1992 at 21 centers in North America and Europe. In 1997, a long-term study continued, including 725 ...

متن کامل

Comparison of the effects of aortic valve replacement using 19-mm Carpentier-Edwards Perimount bioprosthesis and 19-mm Medtronic Mosaic bioprosthesis.

OBJECTIVE Short (< or =3 months)- and middle (> or =4 months)-term results of aortic valve replacement (AVR) using 19-mm Carpentier-Edwards Perimount (CEP) bioprosthetic valves and 19-mm Medtronic Mosaic (MM) bioprosthetic valves in patients with small aortic annulus were compared. PATIENTS AND METHODS At our facility, AVR was performed using bioprostheses in 110 patients from April 1999 to M...

متن کامل

Comparison of early haemodynamics of 19-mm aortic valve bioprostheses in patients with a small aortic annulus.

OBJECTIVES A potential problem in aortic valve replacement (AVR) for patients with a small aortic annulus is prosthesis-patient mismatch (PPM). Although larger size prostheses have been well studied, the haemodynamics of 19-mm bioprostheses has been reported in only a small number of patients. The Trifecta valve is a novel bioprosthesis and its unique design is conceived to increase effective o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 31  شماره 

صفحات  -

تاریخ انتشار 2016