Uncalibrated pulse power analysis fails to reliably measure cardiac output in patients undergoing coronary artery bypass surgery

نویسندگان

  • Ole Broch
  • Jochen Renner
  • Jan Höcker
  • Matthias Gruenewald
  • Patrick Meybohm
  • Jan Schöttler
  • Markus Steinfath
  • Berthold Bein
چکیده

INTRODUCTION Uncalibrated arterial pulse power analysis has been recently introduced for continuous monitoring of cardiac index (CI). The aim of the present study was to compare the accuracy of arterial pulse power analysis with intermittent transpulmonary thermodilution (TPTD) before and after cardiopulmonary bypass (CPB). METHODS Forty-two patients scheduled for elective coronary surgery were studied after induction of anaesthesia, before and after CPB respectively. Each patient was monitored with the pulse contour cardiac output (PiCCO) system, a central venous line and the recently introduced LiDCO monitoring system. Haemodynamic variables included measurement of CI derived by transpulmonary thermodilution (CITPTD) or CI derived by pulse power analysis (CIPP), before and after calibration (CIPPnon-cal., CIPPcal.). Percentage changes of CI (ΔCITPTD, ΔCIPPnon-cal./PPcal.) were calculated to analyse directional changes. RESULTS Before CPB there was no significant correlation between CIPPnon-cal. and CITPTD (r2 = 0.04, P = 0.08) with a percentage error (PE) of 86%. Higher mean arterial pressure (MAP) values were significantly correlated with higher CIPPnon-cal. (r2 = 0.26, P < 0.0001). After CPB, CIPPcal. revealed a significant correlation compared with CITPTD (r2 = 0.77, P < 0.0001) with PE of 28%. Changes in CIPPcal. (ΔCIPPcal.) showed a correlation with changes in CITPTD (ΔCITPTD) only after CPB (r2 = 0.52, P = 0.005). CONCLUSIONS Uncalibrated pulse power analysis was significantly influenced by MAP and was not able to reliably measure CI compared with TPTD. Calibration improved accuracy, but pulse power analysis was still not consistently interchangeable with TPTD. Only calibrated pulse power analysis was able to reliably track haemodynamic changes and trends.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery bypass grafting.

BACKGROUND Cardiac output monitoring, as a part of a goal-directed haemodynamic management, has been shown to improve perioperative outcome in high-risk patients undergoing major surgical interventions. However, thorough validation of cardiac output monitoring devices in different clinical conditions is warranted. The aim of our study was to compare the reliability of a novel system for cardiac...

متن کامل

A Comparison of Third-Generation Semi-Invasive Arterial Waveform Analysis with Thermodilution in Patients Undergoing Coronary Surgery

Uncalibrated semi-invasive continous monitoring of cardiac index (CI) has recently gained increasing interest. The aim of the present study was to compare the accuracy of CI determination based on arterial waveform analysis with transpulmonary thermodilution. Fifty patients scheduled for elective coronary surgery were studied after induction of anaesthesia and before and after cardiopulmonary b...

متن کامل

Use of Carbon dioxide versus air blower in on-pump beating-heart coronary artery bypass surgery

Introduction:  The use of carbon dioxide blower has been recognized as the standard of care in patients undergoing beating coronary artery bypass grafting (CABG) due to higher solubility and lower risk of embolization. On the other hand, the compressed air blower has gone out of use since air can be easily trapped and is less soluble which can cause coronary embolism. The prese...

متن کامل

Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting.

BACKGROUND AND OBJECTIVE During off-pump coronary bypass grafting, surgical manipulation and dislocation of the heart may cause cardiovascular instability. Monitoring of cardiac output facilitates intraoperative haemodynamic management but pulmonary artery catheters are often considered too invasive. Pulse contour analysis and transoesophageal echocardiography could serve as alternatives, but t...

متن کامل

The effect of cardiac rehabilitation on hemodynamic status in patients after coronary artery bypass surgery

Background: Today, coronary artery bypass graft surgery (CABG) in many patients is commonly used to treat complications of the disease. Aim: This study aimed to evaluate the impact of cardiac rehabilitation on hemodynamic parameters in patients undergoing CABG. Methods: : In this clinical trial which was conducted in Rajaee Hospital of Tehran University of Medical Sciences 100 patients after co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2011