Infrared Spectroscopy with a Cavity Ring-Down Spectrometer
نویسندگان
چکیده
منابع مشابه
On-chip spectroscopy with thermally tuned high-Q photonic crystal cavities
Articles you may be interested in High sensitivity and high Q-factor nanoslotted parallel quadrabeam photonic crystal cavity for real-time and label-free sensing Appl. Photonic crystal slot waveguide absorption spectrometer for on-chip near-infrared spectroscopy of xylene in water Appl. Measurements of total peroxy and alkyl nitrate abundances in laboratory-generated gas samples by thermal diss...
متن کاملOptical frequency comb spectroscopy.
Optical frequency combs offer enormous potential in the detection and control of atoms and molecules by combining their vast spectral coverage with the extremely high spectral resolution of each individual comb component. Sensitive and multiplexed trace gas detection via cavity-enhanced direct frequency comb spectroscopy has been demonstrated for various molecules and applications; however, pre...
متن کاملDevelopment of broadband cavity ring-down spectroscopy for biomedical diagnostics of liquid analytes.
We present a spectrometer for sensitive absorption measurements in liquids across broad spectral bandwidths. The spectrometer combines the unique spectral properties of incoherent supercontinuum light sources with the advantages of cavity ring-down spectroscopy, which is a self-calibrating technique. A custom-built avalanche photodiode array is used for detection, permitting the simultaneous me...
متن کاملPound-Drever-Hall-locked, frequency-stabilized cavity ring-down spectrometer.
We describe a high sensitivity and high spectral resolution laser absorption spectrometer based upon the frequency-stabilized cavity ring-down spectroscopy (FS-CRDS) technique. We used the Pound-Drever-Hall (PDH) method to lock the probe laser to the high-finesse ring-down cavity. We show that the concomitant narrowing of the probe laser line width leads to dramatically increased ring-down even...
متن کاملCavity ring-down spectroscopy of Doppler-broadened absorption line with sub-MHz absolute frequency accuracy.
A continuous-wave cavity ring-down spectrometer has been built for precise determination of absolute frequencies of Doppler-broadened absorption lines. Using a thermo-stabilized Fabry-Pérot interferometer and Rb frequency references at the 780 nm and 795 nm, 0.1 - 0.6 MHz absolute frequency accuracy has been achieved in the 775-800 nm region. A water absorption line at 12579 cm(-1) is studied t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014