Comparison of retention and stability of two implant-retained overdentures based on implant location.

نویسندگان

  • Michael D Scherer
  • Edwin A McGlumphy
  • Robert R Seghi
  • Wayne V Campagni
چکیده

STATEMENT OF PROBLEM The location of dental implants and the choice of retentive attachments for implant-retained overdentures are selected based on clinician preference, expert opinion, or empirical information. Limited information is available regarding implant position and the effect on the retention and stability of 2-implant mandibular implant overdentures. PURPOSE The purpose of this investigation was to evaluate the effect of implant location on the in vitro retention and stability of a simulated 2-implant-supported overdenture and to examine the differences among different attachment systems. MATERIAL AND METHODS A model that simulates a mandibular edentulous ridge with dental implants in positions that approximate tooth positions, and a cobalt-chromium cast framework attached to a universal testing machine was used to measure the peak load (N) required to disconnect the attachments. Four different types of attachments (Ball/Cap, ERA, Locator, and O-Ring) were used in sequence in various positions on the model to evaluate the effect of implant location on the retention and stability of a simulated 2-implant-retained overdenture. Means were calculated, and differences among the systems, directions, and groups were identified by using a repeated measured ANOVA (α=.05). For differences observed between measurements, the Bonferroni post hoc method at the 5% level of significance was used to determine the location and magnitude of difference. RESULTS The interactions between the attachment system, direction of force, and implant location were statistically significant (P=.01). The vertical retention and horizontal stability of a simulated overdenture prosthesis increased with the distal implant location up to the second premolar, and the anteroposterior stability increased with distal implant location. The attachment type affected retention and stability differently by location. Ball attachments produced the highest levels of retention and stability, followed by Locator (pink), O-Ring, and ERA (orange). CONCLUSIONS The retention and stability of a 2-implant simulated overdenture prosthesis is significantly affected by implant location (P=.01) and abutment type (P=.01).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

FEM analysis of single implant reaineded mandibular overdenture with four different attachment types: A review

Background: Dentistry science has evolved over the years. According to a 2012 report, submitted by epidemiology department, it was found that 62% people completely lose their teeth out of which 19.2% in mandibular area and 12.2% in maxilla. So the study is done with a specific focus on design of new attachment, in order to increase retention and stability of single implant retained overdentures...

متن کامل

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...

متن کامل

Tooth and implant supported over denture : a case report

Corresponding author:Dr. AvneetKaur,Department of Prosthodontics, Mahatma Gandhi Medical College and Hospital Jaipur. This article may be cited as:Kaur A, Padiyar N Kaurani P and Meena S Tooth and implant supported over denture: a case report2017;3(2):33-36 Article Received: 08-02-17 Accepted On: 23-02-2017 NTRODUCTION Overdenture treatment uses a removable complete denture that overlies retain...

متن کامل

Use of an Implant O-Ring Attachment for the Tooth Supported Mandibular Overdenture: A Clinical Report

Retention of a mandibular denture can be achieved by an implant-retained or natural tooth-retained bar and stud attachment in the anterior segment of the mandible. The same design principles holds true for both implant-retained and tooth-retained methods of anchoring the bar and stud attachment. A simple and cost effective treatment for more complex implant overdenture is the concept of convent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 112 3  شماره 

صفحات  -

تاریخ انتشار 2014