Image fusion of coronary tree and regional cardiac function image using multislice computed tomography.

نویسندگان

  • Hiroshi Higashino
  • Teruhito Mochizuki
  • Toyoaki Haraikawa
  • Akira Kurata
  • Teruhito Kido
  • Shigeru Nakata
  • Yoshifumi Sugawara
  • Masao Miyagawa
  • Hitoshi Miki
  • Yasushi Koyama
  • Hideki Okayama
  • Jitsuo Higaki
چکیده

BACKGROUND Although trials of image fusion, such as positron emission computed tomography and multislice spiral computed tomography (MSCT), have already demonstrated clinical usefulness, fusion of the coronary artery image and functional image by MSCT alone has not been reported yet. Here, a new idea of data analysis is proposed in which both regional cardiac function and the responsible coronary arteries can be assessed by a fused image. METHODS AND RESULTS The study group comprised 5 patients with coronary artery disease. At the first procedure, 3 dimensional (D) volume rendering coronary artery (3D-CTA) was extracted. At the second procedure, the systolic regional wall thickening was calculated and the color 3D functional surface map of systolic wall thickening (3D-SWT) was generated. At the final procedure, 3D-SWT was superimposed on the left ventricular surface with 3D-CTA using a transparency. In all 5 patients, image fusion of the coronary tree and cardiac function was correctly generated. Image fusion can be displayed as clear 3D images, offering better orientation to help assess both the coronary artery and regional function. CONCLUSIONS Image fusion of coronary computed tomography angiography and the functional map by MSCT is potentially a new method of assessing both the coronary artery and cardiac function.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multislice Spiral Computed Tomography in Cardiac Imaging

Objective: Multislice computed tomography is an emerging technology with the potential for non-invasive coronary investigation. The aim of this study was to evaluate the feasibility and limitations of multislice computed tomography in the detection of coronary artery disease. Patients and Methods: Multislice computed tomography was performed in symptomatic patients with atypical chest pain and ...

متن کامل

Method comparison for cardiac image registration of coronary computed tomography angiography and 3-D echocardiography.

Treatment decision for coronary artery disease (CAD) is based on both morphological and functional information. Image fusion of coronary computed tomography angiography (CCTA) and three-dimensional echocardiography (3DE) could combine morphology and function into a single image to facilitate diagnosis. Three semiautomatic feature-based methods for CCTA/3DE registration were implemented and appl...

متن کامل

Simulation and patient studies of scatter correction in cardiac SPECT imaging

Introduction: Myocardial perfusion imaging is a nuclear medicine imaging method that is used to detect coronary artery diseases. One of the main sources of error in this imaging method is the detection of Compton scattered photons in the photopeak energy window used for data acquisition. This results in the degradation of the image contrast, and therefore decreases the...

متن کامل

Ablation of idiopathic left ventricular tachycardia using remote magnetic navigation integrated with advanced mapping.

1. García MJ, Lessick J, Hoffmann MH; CATSCAN Study Investigators. Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis. JAMA. 2006;296:403-11. 2. Gaemperli O, Schepis T, Valenta I, Husmann L, Scheffel H, Duerst V, et al. Cardiac image fusion from stand-alone SPECT and CT: clinical experience. J Nucl Med. 2007;48:696-703. 3. Rubinshtein R, Gaspar T...

متن کامل

Assessing the image quality and eye lens dose reduction using bismuth shielding in computed tomography of brain

Background: Epidemiological studies show that computed tomography (CT) is one of the main sources of ionizing radiations. Shielding of radiosensitive organs is one of the dose reduction methods. This study aimed to assess the eye lens dose reduction and image quality resulting from the use of radio-protective bismuth shield in brain CT imaging. Methods: Bismut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 70 1  شماره 

صفحات  -

تاریخ انتشار 2006