Portable blood pressure measurements: performance of Korotkov sound analysis techniques.

نویسندگان

  • R Wolthuis
  • D Hull
  • D MacAfoose
  • J Fischer
چکیده

Noninvasive portable blood pressure systems (PBPS) are typically based on korotkov sound technique. The performance of related Korotkov sound analysis techniques was assessed in PBPS data obtained from nine normotensive and nine hypertensive men. Multiple-seated PBPS measurements were taken, each following 1 minute of quiet rest, moderate walking, and stair climbing; each PBPS measurement was accompanied by a simultaneous auscultatory measurement in the same arm. In subsequent manual PBPS data analysis, PBPS systolic and diastolic BPs were within 4 mm Hg of corresponding auscultatory BPs 86% and 88% of the time; BPs following rest and walking showed greater accuracy, while those following stair climbing were less accurate. Interestingly, automated analysis of diastolic PBPS data (using selective bandpass filtering, amplitude normalization, and comparator decision ratios) provided a level of accuracy similar to that obtained from manual data analysis. Overall, both manual and automated Korotkov sound analysis techniques can provide BP results that agree quite well with auscultatory determinations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement

Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...

متن کامل

Investigation of Noise Levels in Sugar Factory of Debal Khozaei Agro-industry Complex

Introduction and purpose: Noise pollution can exert negative effects on mental health. In this regard, the present study aimed to evaluate the noise levels in sugar factory of Debal Khozaei agro-industry complex in 2018. Methods: For the current study, sound and audio parameters were measured using a sound meter. These audio parameters included sound pressure level and minimum and maximum valu...

متن کامل

Assessment and Control of Noise Pollution in Seal Gas Compressor of Reduction Unit 2 of a Steel Industry

Background and aims: Undoubtedly, noise and vibration are major problems of industrial world and lot of people are very exposed to these phenomena in their workplace or residential areas. Researchers have shown that exposure to noise may increase the risks related to personal health, like nervous frailty, extreme irritability, muscle cramps, stress and anxiety, dizziness, headache and migraine,...

متن کامل

Central arterial pressure and arterial pressure pulse: new views entering the second century after Korotkov.

The ubiquitous brachial cuff method gained widespread clinical acceptance for blood pressure recording after confirmation of its prognostic value in 1917. This method displaced radial pulse waveform analysis by sphygmography, which also gave prognostic Information but was difficult to use. Since that time, brachial cuff sphygmomanometry has migrated from the physician's office to 24-hour monito...

متن کامل

Accuracy of the i-STAT bedside blood gas analyser.

The performance of the i-STAT portable clinical analyser for measuring blood gases and pH was evaluated with reference to a conventional blood gas analyser (ABL520 Radiometer). Ninety-two samples from the routine blood gas analysis laboratory were chosen according to a wide distribution of partial pressure of carbon dioxide (Pa,CO2), partial pressure oxygen (Pa,O2) and pH and then analysed. All...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hypertension

دوره 3 5  شماره 

صفحات  -

تاریخ انتشار 1981