Metal/polypyrrole quasi-reference electrode for voltammetry in nonaqueous and aqueous solutions.
نویسندگان
چکیده
As an alternative to the usual commercial reference and quasi-reference electrodes (QREs), we propose metal (Pt, stainless steel) coated with partially oxidized polypyrrole as a QRE. The electrode is easily fabricated by cyclic voltammetry (CV) with the metal electrode in an acetonitrile or CH2Cl2 solution of 10 mM pyrrole containing 0.1 M Bu4NPF6. These QREs were more stable than the widely used metal (e.g., Ag, Pt) wire QRE as demonstrated by testing in several aqueous and organic media, with the stability checked by CV with ferrocenemethanol as the redox species. The results obtained demonstrate good stability of these QREs over a period of 1 day and relatively reproducible potential in a given solvent and supporting electrolyte. This electrode has the advantage that it does not contaminate the test solution with ions or solvent from a usual liquid electrolyte (e.g., the KCl in an Ag/AgCl). It is also simple to fabricate very small electrodes for use in nanocells, e.g., in scanning tunneling and electrochemical microscopy.
منابع مشابه
On-chip metal/polypyrrole quasi-reference electrodes for robust ISFET operation.
To operate an ion-sensitive field-effect transistor (ISFETs) it is necessary to set the electrolyte potential using a reference electrode. Conventional reference electrodes are bulky, fragile, and too big for applications where the electrolyte volume is small. Several researchers have proposed tackling this issue using a solid-state planar micro-reference electrode or a reference field-effect t...
متن کاملModified Glass Carbon Electrode (GCE) Electropolymerized Polypyrrole Nanofibers with Hemoglobin (Hb) Film as a Unique Biosensor for Nitrite Determination
Abstract: In this study, we were investigated behavior the electrochemical reductionof nitrite at a hemoglobin (Hb) immobilized on glass carbon electrode (GCE) containingpolypyrol nanofiber (ppy) films. Polypyrrole (PPy) nanofibers have been constructed onGCE applying electrochemical technique, and can to deposit diverse polymers onminiaturized electrodes with this commo...
متن کاملElectrochemistry of nanozeolite-immobilized cytochrome c in aqueous and nonaqueous solutions.
The electrochemical properties of cytochrome c (cyt c) immobilized on multilayer nanozeolite-modified electrodes have been examined in aqueous and nonaqueous solutions. Layers of Linde type-L zeolites were assembled on indium tin oxide (ITO) glass electrodes followed by the adsorption of cyt c, primarily via electrostatic interactions, onto modified ITO electrodes. The heme protein displayed a ...
متن کاملConstruction of a Carbon Paste Electrode Based on Novel Thiolated Ligand Capped Gold Nanoparticles for Determination of Trace Amounts of Mercury(II)
In the present study, a simple electrochemical sensor for trace determination of Hg(II) ions in aqueous solutions was introduced. The proposed sensor was designed by incorporation of the 4-methyl-piperidine-carbodithioate capped gold nanoparticles (GNPs) into the carbon paste electrode (CPE), which provides a remarkably improved sensitivity for stripping voltammetric determination of Hg(II). Di...
متن کاملElectrochemical fabrication of polypyrrole nanofibers and their characterization
Polypyrrole (PPy) nanofibers have been fabricated on glassy carbon electrode (GCE) usingelectrochemical technique. Electropolymerization of pyrrole (Py) for the fabrication of PPy nanofiberswas occurred on GCE by applying a fixed potential of about 0.85 V for 120 sec in a mild basic solutioncontaining sodium carbonate and sodium perchlorate. In the mild basic media, the monomer, Py, isoxidized ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 78 19 شماره
صفحات -
تاریخ انتشار 2006