Surveillance on interfacility differences in dose-prescription policy of intensity-modulated radiation therapy plans for prostate cancer

نویسندگان

  • Takashi Mizowaki
  • Kazuo Hatano
  • Masahiro Hiraoka
چکیده

Intensity-modulated radiation therapy (IMRT) has recently become popular in Japan. Prostate cancer is indisputably one of the main targets of IMRT. However, the current status and interfacility differences in dose-prescription policies for prostate IMRT are unknown. Therefore, a nationwide survey of 43 institutions that had implemented prostate IMRT was conducted by sending a questionnaire regarding the above-mentioned issues. Thirty-three institutions (77%) had responded to the questionnaire by the end of October 2010. A total of 5245 patients with localized prostate cancer had been treated with IMRT by the end of 2009. Regular multileaf collimator-based techniques were the most common beam delivery method. Dose-prescription policies were divided into four major categories: isocenter-based (@isocenter), dose delivered to 95% of the planning target volume (PTV) (D95)-based (D95@PTV), mean dose to the PTV-based (Mean@PTV), and mean dose to the clinical target volume (CTV)-based (@CTV). The mean doses of the CTV and PTV, and the volume of the PTV receiving 95% of the dose (V95) were significantly higher with the D95@PTV policy than with the other prescription policies. Low-dose areas and hot spots were observed within the PTV in plans with @isocenter and @CTV policies. In conclusion, there are currently considerable differences among institutions in Japan regarding target doses for prostate IMRT. The D95@PTV prescription policy resulted in significant dose escalation compared with the other policies. These differences should be taken into consideration when interpreting treatment outcomes and creating multi-institutional protocols in the future.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

متن کامل

Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...

متن کامل

The Relationship between the Different Prostate Intensity Modulated Radiation Therapy Techniques and Patient’s Anatomical Parameters

Introduction: Intensity Modulated Radiotherapy (IMRT) is a common method for treating prostate cancers. Different IMRT methods can apply for irradiating the prostate, but there is not clear that which of these methods can provide better dose distribution for each patient individually. Therefore, the aim of this study was to evaluate the relationship between the different prosta...

متن کامل

The Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography

Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...

متن کامل

Out-of-field photon dosimetry study between 3-D conformal and intensity modulated radiation therapy in the management of prostate cancer

Background: The present work aims to study the out-of-field photon calculation accuracy of a commercial treatment planning system (TPS), Oncentra, for three-dimensional conformal radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) treatment techniques from Elekta Synergy medical linear accelerator. Materials and Methods: Accuracy of individual out-of-field dose components was...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 53  شماره 

صفحات  -

تاریخ انتشار 2012