Ventilation and Air Quality in Indoor Ice Skating Arenas

نویسندگان

  • Chunxin Yang
  • Philip Demokritou
  • Qingyan Chen
  • John Spengler
  • Austin Parsons
چکیده

There are thousands of indoor ice rink arenas in the United States, Canada, and Europe. The combustion byproducts from the fuel powered ice resurfacing equipment impose a potential health risk to both athletes and spectators. A field survey of ten ice rink arenas in Greater Boston and Halifax, Nova Scotia indicates that the fuel type used by the resurfacer as well as the air exchange rate, the air distribution method, and the operation strategy of the ventilation system are significant contributing factors to the indoor air quality (IAQ). Computational fluid dynamics (CFD) has been used to systematically investigate the impact of air exchange rate, air distribution method, and ventilation control strategies on the IAQ in an arena. With CFD, it is possible to develop design and operating guidelines for ventilation systems in order to reduce contamination levels in the arenas.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carbon monoxide poisoning at an indoor ice arena and bingo hall--Seattle, 1996. From the Centers for Disease Control and Prevention.

On March 16, 1996, paramedics and fire department personnel were requested to evaluate complaints of illness among persons exposed to exhaust fumes in an indoor ice skating facility in Seattle. Indoor-air measurements detected elevated levels of carbon monoxide (CO), prompting evacuation of the building. An investigation of the cluster of CO poisonings related to the exposure was conducted Marc...

متن کامل

Experimental validation of a computational fluid dynamics model for IAQ applications in ice rink arenas.

Many ice rink arenas have ice resurfacing equipment that uses fossil fuel as power. The combustion byproducts are a major source of contamination. Ventilation along with other pollution source control measures is the most widely applied strategy to lower the contaminant level below the threshold limit and maintain acceptable indoor air quality (IAQ). A computational fluid dynamics (CFD) model h...

متن کامل

An experimental method for contaminant dispersal characterization in large industrial buildings for IAQ applications

Spatial contaminant distribution in large semiopen building areas such as sports arenas, warehouses, atriums, malls and other industrial halls is critical to estimating exposure, health risks and building energy performance. It is considered a challenge to measure experimentally how effectively the ventilation system removes or dilutes the pollutant in a large open space, taking into considerat...

متن کامل

Natural Ventilation: Analysis of Indoor Airflow in an Assumed Cubic Building with Opposite Openings by CFD Investigations

The natural ventilation is an easy way to exchange the indoor polluted warm air with outdoor fresh air. The wind power injects outdoor fresh air into the building. A good indoor air current and subsequently a proper exhaust depend on the openings’ conditions and their situations. A serious architectural question is under what conditions of the openings the wind-cross ventilation can be effectiv...

متن کامل

بررسی آلاینده های شاخص هوای داخل و خارج منازل مسکونی شهری

Background and purpose: Indoor air pollution in developing countries is considered as one of the main problems in healthcare. This study aimed at investigating the levels of indoor/outdoor air pollutants in Khorramabad during autumn and winter 2012. Materials and methods: In a cross-sectional study, nine gas concentrations and particulate pollutants were measured using air pollution measuring ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006