An approach for measuring the spatial orientations of a computed‐tomography simulation system

نویسندگان

  • Meng Chia Wu
  • Ramani Ramaseshan
چکیده

The quality assurance tests for measuring the spatial orientations between tabletop, external patient positioning lasers, couch longitudinal moving direction, and imaging plane in a CT simulation system are a complicated and time-consuming process. We proposed a simple and efficient approach to acquire the angular deviations of spatial orientations between these components. An in-house cross-jig was used in this study. We found a relationship between the orientations of the jig's arms shown on the CT images and the orientations of the components in a CT simulator. We verified this relationship with 16 misalignment orientations of known errors, to simulate all possible deviation situations. Generally, the tabletop and external lasers system are mounted separately in a CT simulation system; the former is on the couch trail, the later is on the wall and ceiling. They are independent to each other and will cause different effects on CT images. We only need two scans to acquire the angular deviations of our system: i) when aligning the cross-jig with tabletop, we can check the orientations between the tabletop, couch longitudinal moving direction, and imaging plane; ii) while aligning the cross-jig with the external axial lasers, we will know the angular deviation between the lasers, couch longitudinal moving direction, and imaging plane. The CT simulator had been carefully examined by performing the QA procedures recommended by the AAPM Task Group 66. The measurements of the spatial orientations using the proposed method agree well with TG 66 recommendations. However, the time taken to perform the QA using our method is considerably shorter than the method described in TG 66--5 minutes versus 30 minutes. The deliberate misalignment orientations tests with known errors were detected successfully by our in-house analysis program. The maximum difference between the known errors and the measured angles is only 0.07°. We determined that the relationship between the orientations of the jig's arms and the orientations of the CT components. By means of quantifying the deviations in degree we can correct the errors accurately. This approach can also be used to inspect the spatial orientations of other imaging systems, such as PET-CT and MRI.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies

Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...

متن کامل

Siemens primus accelerator simulation using EGSnrc Monte Carlo code and gel dosimetry validation with optical computed tomography system by EGSnrc code

Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...

متن کامل

Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography

Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...

متن کامل

Image Optimization in Single Photon Emission Computed Tomography by Hardware Modifications with Monte Carlo Simulation

Introduction: In Single Photon Emission Computed Tomography (SPECT), the projection data used for image reconstruction are distorted by several factors, including attenuation and scattering of gamma rays, collimator structure, data acquisition method, organ motion, and washout of radiopharmaceuticals. All these make reconstruction of a quantitative SPECT image very difficult. Simulation of a SP...

متن کامل

Design and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems

Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014