Feasibility of a novel atrioventricular delay optimization method using transmitral and pulmonary venous flow in patients with sequential ventricular pacing or cardiac resynchronization therapy
نویسندگان
چکیده
BACKGROUND Although several echo-Doppler methods were proposed to optimize atrioventricular (AV) delay in patients with sequential ventricular pacing, "echo-guided" AV optimization has not been widely adopted clinically. A combination of trasmitral flow (TMF) and pulmonary venous flow (PVF) measurements may be beneficial to further optimize AV delay to achieve better cardiac function. The aim of this study was to assess the feasibility and usefulness of AV delay optimization by combined use of TMF and PVF. METHODS A total of 32 patients after sequential ventricular pacemaker implantation were enrolled and studied. The optimal AV delay was defined as the timing to minimize the duration between PVF reversal (a) wave and the duration of the "A" wave of TMF. Stroke volume was measured at the "optimized" AV delay (AVD(OPT)) and was compared with that obtained at shorter (AVD(OPT) - 50 ms) and longer (AVD(OPT) + 50 ms) AV delays. RESULTS AV optimization was feasible in 27 of 32 patients (87%). Stroke volume at AVD(OPT) was significantly higher than that at shorter or longer AV delay (63 ± 18 ml vs. 57 ± 15 ml vs. 56 ± 16 ml, P = 0.001). CONCLUSIONS AV delay optimization using TMF and PV flow was feasible. Usefulness of this method requires further investigation with a larger study population.
منابع مشابه
Resynchronization therapy optimization by intracardiac impedance.
AIMS For successful cardiac resynchronization therapy (CRT), an optimization of left ventricular (LV) lead position and stimulation timing is required. The feasibility of optimizing LV lead position, atrioventricular delay (AVd), and interventricular delay (VVd) in CRT using intracardiac impedance measurement was evaluated. METHODS AND RESULTS Heart failure patients (n = 14, NYHA 13×III, 1×II...
متن کاملEcho-driven V-V optimization determines clinical improvement in non responders to cardiac resynchronization treatment
Echocardiography plays an integral role in the detection of mechanical dyssynchrony in patients with congestive heart failure and in predicting beneficial response to cardiac resynchronization treatment. In patients who derive sup-optimal benefit from biventricular pacing, optimization of atrioventricular delay post cardiac resynchronization treatment has been shown to improve cardiac output. S...
متن کاملAtrioventricular and interventricular delay optimization and response quantification in biventricular pacing: arrival of reliable clinical algorithms and research protocols, and how to distinguish them from unreliable counterparts.
In this issue of the journal, Bogaard et al. assess the achievable haemodynamic increment within individuals of optimizing atrioventricular (AV) and interventricular (VV) delays. Biventricular pacing, or cardiac resynchronization therapy (CRT), arguably the greatest advancement in the treatment of heart failure in the last decade, causes immediate increases in haemodynamics and then improvement...
متن کاملValidation of a peak endocardial acceleration-based algorithm to optimize cardiac resynchronization: early clinical results
AIMS Cardiac resynchronization therapy (CRT) involves time-consuming procedures to achieve an optimal programming of the system, at implant as well as during follow-up, when remodelling occurs. A device equipped with an implantable sensor able to measure peak endocardial acceleration (PEA) has been recently developed to monitor cardiac function and to guide CRT programming. During scanning of t...
متن کاملProgramming Cardiac Resynchronization Therapy for Electrical Synchrony: Reaching Beyond Left Bundle Branch Block and Left Ventricular Activation Delay
BACKGROUND QRS narrowing following cardiac resynchronization therapy with biventricular (BiV) or left ventricular (LV) pacing is likely affected by patient-specific conduction characteristics (PR, qLV, LV-paced propagation interval), making a universal programming strategy likely ineffective. We tested these factors using a novel, device-based algorithm (SyncAV) that automatically adjusts paced...