Biomechanical comparison of unilateral semi-rigid and dynamic stabilization on ovine vertebrae.
نویسندگان
چکیده
Using the unilateral pedicle screw fixation was thought to decrease the stiffness of the fixed segments. Various prospective, randomized studies were performed to determine whether unilateral pedicle screw fixation provides the necessities of bilateral fixation in one- or two-segment lumbar spinal fusion. In this study, four different unilateral pedicle screw fixation systems were evaluated to determine which one best approximated an intact spine with respect to biomechanics and kinematics. The four groups included an intact group, a unilateral facetectomy group with no fixation, a unilateral semi-rigid pedicle screw fixation group with a poly-ether-ether-ketone rod, and a unilateral dynamic pedicle screw fixation group. The bone mineral densities of all specimens were measured and specimens were matched with groups randomly. Flexion, lateral bending, and axial rotation tests were performed to compare the groups. For the flexion, lateral bending, and axial rotation tests, the best biomechanical outcomes were in the control group. The unilateral facetectomy group had the poorest performance and was not stable enough, compared with the control group. The dynamic and semi-rigid groups showed performance closer to that of the control group. The biomechanical responses of these two groups were also in good agreement, showing no significant statistical differences. Based on these test results, it is concluded that the unilateral dynamic and semi-rigid pedicle screw fixations can be used to provide stability to the vertebrae.
منابع مشابه
Static and dynamic nonlinear analysis of steel frame with semi-rigid connections
One of the important issues in the study of steel frames is to find a suitable formulation for semi-rigid connections. In this paper, the explicit stiffness matrix for a two-dimensional beam-column element having end-flexibilities is derived. The effects of the lateral uniformly distributed load on the deflection are considered. Both tensile and compressive axial loads are also taken into accou...
متن کاملNonlinear inelastic dynamic analysis of space steel frames with semi-rigid connections in urban buildings
Applied studies addressing semi-rigid connections have been limited. Scant information exists in regulations except little brief information. Therefore, this research analyzes the behavior of three-dimensional steel frames and semi-rigid connections based on beam-column method and non-linear dynamic analysis. Stability functions and geometric stiffness matrix were used to study the non-linear g...
متن کاملEvaluation of Nonlinear Dynamic Response of Rigid and Semi-Rigid Steel Frames under Far-Field Earthquake Records
The purpose of this research was to evaluate the nonlinear dynamic response of rigid and semi-rigid steel frames under Far-Fault Earthquake Records. Accordingly, the fragility curve of the moment frames with rigid and semi-rigid connections was determined. Considering the analytical knowledge of structures in the past, the analysis and design of steel frames based on the assumptions of rigid or...
متن کاملBiomechanical Analysis of the Influence of SACH Foot and Dynamic-Response Foot in Individual With Unilateral Transtibial Amputee During Running
Objective: Amputation of the lower limb due to loss of part of the musculoskeletal structure reduces performance and increases injury during locomotion. The effect of various types of prosthetic feet has been analyzed in several studies during running. The purpose of this study was a biomechanical analysis of the influence of SACH and Dynamic-Response foot on several kinetic variables in the st...
متن کاملBiomechanical comparison of two stabilization techniques of the atlantoaxial joints: transarticular screw fixation versus screw and rod fixation.
OBJECTIVE To compare the biomechanical stability imparted to the C1 and C2 vertebrae by either transarticular screw fixation (TSF) or screw and rod fixation (SRF) techniques in a cadaver model. METHODS Ten fresh ligamentous human cervical spine specimens were harvested from cadavers. The specimens were tested sequentially in the intact state, after injury and stabilization (unilateral left si...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
دوره 229 11 شماره
صفحات -
تاریخ انتشار 2015